Notifications
You must be signed in to change notification settings - Fork 9
Open
Description
- Determine the uncertainty of limited diameter of the waste pipe on head tank turbulence, potentially adding another 1 in waste pipe?
- How does throttle valve affect the flow, and ways to fine tune
- peristaltic pump flow rate uncertainty
* look at manufacturer for errors - Uncertainty created by sump pump
- Height of water in air chamber
*monroe or cowen for ideas to measure height of water - air leakage in air chamber
* seal it better, maybe screw cap? idk :) - Measurement of slack on middle spring, instead of measuring how much excess of the loop, should measure the size of the loop
- the stiffness of the string
Metadata
Metadata
Assignees
Labels
No labels