It seems in some cases it might come to an error when loading an AUX RRC product:
<ows:Exception locator="ValueError" exceptionCode="NoApplicableCode">
<ows:ExceptionText>all the input array dimensions except for the concatenation axis must match exactly</ows:ExceptionText>
</ows:Exception>
Example product with issue:
AE_OPER_AUX_RRC_1B_20190909T181547_20190909T183159_0001
Example request:
<wps:Execute version="1.0.0" service="WPS" xmlns:wps="http://www.opengis.net/wps/1.0.0" xmlns:ows="http://www.opengis.net/ows/1.1">
<ows:Identifier>aeolus:level1B:AUX:RRC</ows:Identifier>
<wps:DataInputs>
<wps:Input>
<ows:Identifier>collection_ids</ows:Identifier>
<wps:Data>
<wps:ComplexData mimeType="application/json">
<![CDATA[["AUX_RRC_1B","user_collection_test"]]]>
</wps:ComplexData>
</wps:Data>
</wps:Input>
<wps:Input>
<ows:Identifier>begin_time</ows:Identifier>
<wps:Data>
<wps:LiteralData>2019-09-09T15:18:56.899Z</wps:LiteralData>
</wps:Data>
</wps:Input>
<wps:Input>
<ows:Identifier>end_time</ows:Identifier>
<wps:Data>
<wps:LiteralData>2019-09-09T23:35:24.175Z</wps:LiteralData>
</wps:Data>
</wps:Input>
<wps:Input>
<ows:Identifier>fields</ows:Identifier>
<wps:Data> <wps:LiteralData>altitude,satellite_range,geoid_separation_obs,normalised_useful_signal,lat_of_DEM_intersection,lon_of_DEM_intersection,time_freq_step,frequency_offset,frequency_valid,ground_frequency_valid,measurement_response,measurement_response_valid,measurement_error_rayleigh_response,reference_pulse_response,reference_pulse_response_valid,reference_pulse_error_rayleigh_response,ground_measurement_response,ground_measurement_response_valid,ground_measurement_error_rayleigh_response,num_measurements_usable,num_valid_measurements,num_reference_pulses_usable,num_measurements_valid_ground,measurement_mean_sensitivity,measurement_zero_frequency,measurement_error_rayleigh_response_std_dev,measurement_offset_frequency,measurement_error_fit_coefficient,reference_pulse_mean_sensitivity,reference_pulse_zero_frequency,reference_pulse_error_rayleigh_response_std_dev,reference_pulse_offset_frequency,reference_pulse_error_fit_coefficient,ground_measurement_mean_sensitivity,ground_measurement_zero_frequency,ground_measurement_error_rayleigh_response_std_dev,ground_measurement_offset_frequency,ground_measurement_error_fit_coefficient,satisfied_min_valid_freq_steps_per_cal,satisfied_min_valid_ground_freq_steps_per_cal,freq_offset_data_monotonic,num_of_valid_frequency_steps,num_of_valid_ground_frequency_steps,measurement_mean_sensitivity_valid,measurement_error_response_std_dev_valid,measurement_zero_frequency_response_valid,measurement_data_monotonic,reference_pulse_mean_sensitivity_valid,reference_pulse_error_response_std_dev_valid,reference_pulse_zero_frequency_response_valid,reference_pulse_data_monotonic,ground_measurement_mean_sensitivity_valid,ground_measurement_error_response_std_dev_valid,ground_measurement_zero_frequency_response_valid,ground_measurement_data_monotonic,rayleigh_spectrometer_temperature_9,rayleigh_spectrometer_temperature_10,rayleigh_spectrometer_temperature_11,rayleigh_thermal_hood_temperature_1,rayleigh_thermal_hood_temperature_2,rayleigh_thermal_hood_temperature_3,rayleigh_thermal_hood_temperature_4,rayleigh_optical_baseplate_avg_temperature</wps:LiteralData>
</wps:Data>
</wps:Input>
</wps:DataInputs>
<wps:ResponseForm>
<wps:RawDataOutput mimeType="application/msgpack">
<ows:Identifier>output</ows:Identifier>
</wps:RawDataOutput>
</wps:ResponseForm>
</wps:Execute>