I'm trying to create a RAID 50 array with two logical disks on a newer Proliant DL380 Gen 11 server. I suspect I'm missing some parameters required for RAID50, but do not find any info on this.
Note that a RAID5 array creates as expected.
- HPE ProLiant DL380 Gen11
- System ROM: U54 v2.34 (10/04/2024)
- iLO Firmware Version: 1.65 Nov 12, 2024
- HPE MR416i-o Gen11
Here's the command I'm running along with the failure response.
ilorest createvolume volume RAID50 1:1:1,1:1:2,1:1:3,1:1:4,1:7:1,1:7:2,1:7:3,1:7:4,2:2:1,2:2:2,2:2:3,2:2:4,2:3:1,2:3:2,2:3:3,2:3:4 --DisplayName data --controller=0 --storageid=DE00C000 --url=x.x.x.x --user user1 --password password1
iLORest : RESTful Interface Tool version 6.0.0.0
Copyright (c) 2014-2025 Hewlett Packard Enterprise Development LP
Discovering data...Done
CreateVolume path and payload: /redfish/v1/Systems/1/Storage/DE00C000/Volumes, {'Links': {'Drives': [{'@odata.id': '/redfish/v1/Chassis/DE00C002/Drives/0'}, {'@odata.id': '/redfish/v1/Chassis/DE00C002/Drives/1'}, {'@odata.id': '/redfish/v1/Chassis/DE00C003/Drives/2'}, {'@odata.id': '/redfish/v1/Chassis/DE00C003/Drives/3'}, {'@odata.id': '/redfish/v1/Chassis/DE00C003/Drives/4'}, {'@odata.id': '/redfish/v1/Chassis/DE00C003/Drives/5'}, {'@odata.id': '/redfish/v1/Chassis/DE00C000/Drives/6'}, {'@odata.id': '/redfish/v1/Chassis/DE00C000/Drives/7'}, {'@odata.id': '/redfish/v1/Chassis/DE00C000/Drives/8'}, {'@odata.id': '/redfish/v1/Chassis/DE00C000/Drives/9'}, {'@odata.id': '/redfish/v1/Chassis/DE00C001/Drives/10'}, {'@odata.id': '/redfish/v1/Chassis/DE00C001/Drives/11'}, {'@odata.id': '/redfish/v1/Chassis/DE00C001/Drives/12'}, {'@odata.id': '/redfish/v1/Chassis/DE00C002/Drives/13'}, {'@odata.id': '/redfish/v1/Chassis/DE00C002/Drives/14'}, {'@odata.id': '/redfish/v1/Chassis/DE00C001/Drives/15'}]}, 'RAIDType': 'RAID50', 'DisplayName': 'data'}
iLO.2.30.UnsupportedOperation
ERROR : iLO threw iLOResponseError
ERROR : iLO threw iLOResponseError