Skip to content

Radio RX timeout when data rate is greater than 2. #1624

@maivananh111

Description

@maivananh111

I am using sx1262 and source code from this repository to implement a LoRaWAN end device class A 1.0.3, region AS923 with ADR enabled, join and uplink process is ok, however it cannot receive downlink or confirm every time ADR is enabled and DR is greater than 2, like 3, 4, 5. After DR is decremented each time even DR2 cannot receive downlink, however if ADR is disabled and everything happens only at DR2 then there is no problem. I think the problem is not in the hardware, because the normal transmission and reception tests are normal. LoRaWAN 1.0.2 uses a different code on this hardware and it works fine and can receive downlinks at DR3, 4, 5. I noticed that every time the RadioSetRxConfig function is called with DR greater than 2, then RadioRx is called, the SX1262 immediately generates a TX_RX_TIMEOUT interrupt, which is not the RX timeout timer. This Radio library for version 1.0.3 was used for version 1.0.2 but did not have this problem. I checked on the gateway as a server, it does send downlinks to the terminal. What is the cause of this problem? Thanks.