Boost 5 Click demo application is developed using the NECTO Studio, ensuring compatibility with mikroSDK's open-source libraries and tools. Designed for plug-and-play implementation and testing, the demo is fully compatible with all development, starter, and mikromedia boards featuring a mikroBUS™ socket.
- Author : Stefan Filipovic
- Date : Jan 2025.
- Type : ADC type
This example demonstrates the use of the Boost 5 Click board by enabling the device and continuously reading and logging the measured output voltage (VOUT). If a failure is detected during voltage reading, the device is reset.
- MikroSDK.Board
- MikroSDK.Log
- Click.Boost5
boost5_cfg_setup
This function initializes Click configuration structure to initial values.
void boost5_cfg_setup ( boost5_cfg_t *cfg );
boost5_init
This function initializes all necessary pins and peripherals used for this Click board.
err_t boost5_init ( boost5_t *ctx, boost5_cfg_t *cfg );
boost5_enable_device
This function enables device by setting the EN pin to high logic state.
void boost5_enable_device ( boost5_t *ctx );
boost5_reset_device
This function resets device by toggling the EN pin logic state.
void boost5_reset_device ( boost5_t *ctx );
boost5_read_vout
This function reads the boost output voltage level.
err_t boost5_read_vout ( boost5_t *ctx, float *vout );
Initializes the logger and the Boost 5 Click board. Configures the ADC for voltage measurements and enables the device to prepare it for operation.
void application_init ( void )
{
log_cfg_t log_cfg; /**< Logger config object. */
boost5_cfg_t boost5_cfg; /**< Click config object. */
/**
* Logger initialization.
* Default baud rate: 115200
* Default log level: LOG_LEVEL_DEBUG
* @note If USB_UART_RX and USB_UART_TX
* are defined as HAL_PIN_NC, you will
* need to define them manually for log to work.
* See @b LOG_MAP_USB_UART macro definition for detailed explanation.
*/
LOG_MAP_USB_UART( log_cfg );
log_init( &logger, &log_cfg );
log_info( &logger, " Application Init " );
// Click initialization.
boost5_cfg_setup( &boost5_cfg );
BOOST5_MAP_MIKROBUS( boost5_cfg, MIKROBUS_1 );
if ( ADC_ERROR == boost5_init( &boost5, &boost5_cfg ) )
{
log_error( &logger, " Communication init." );
for ( ; ; );
}
log_printf( &logger, "\r\n Enable device\r\n\n" );
boost5_enable_device ( &boost5 );
log_info( &logger, " Application Task " );
}
Reads the output voltage level and logs it on the USB UART. In case of an error during the reading process, or the user changes VOUT using an on-board VOUT SEL switch, the device is reset to recover from potential issues or to apply new settings.
void application_task ( void )
{
float vout = 0;
if ( BOOST5_OK == boost5_read_vout ( &boost5, &vout ) )
{
log_printf( &logger, "\r\n VOUT : %.3f V\r\n", vout );
}
else
{
log_printf( &logger, "\r\n Reset device\r\n" );
boost5_reset_device ( &boost5 );
}
}
The VOUT is configured using an on-board VOUT SEL 4-position switch.
This Click board can be interfaced and monitored in two ways:
- Application Output - Use the "Application Output" window in Debug mode for real-time data monitoring. Set it up properly by following this tutorial.
- UART Terminal - Monitor data via the UART Terminal using a USB to UART converter. For detailed instructions, check out this tutorial.