Hall Current 17 Click demo application is developed using the NECTO Studio, ensuring compatibility with mikroSDK's open-source libraries and tools. Designed for plug-and-play implementation and testing, the demo is fully compatible with all development, starter, and mikromedia boards featuring a mikroBUS™ socket.
- Author : Nenad Filipovic
- Date : Aug 2023.
- Type : SPI type
This example demonstrates the use of Hall Current 17 Click board™ by reading and displaying the current measurements.
- MikroSDK.Board
- MikroSDK.Log
- Click.HallCurrent17
hallcurrent17_cfg_setup
Config Object Initialization function.
void hallcurrent17_cfg_setup ( hallcurrent17_cfg_t *cfg );
hallcurrent17_init
Initialization function.
err_t hallcurrent17_init ( hallcurrent17_t *ctx, hallcurrent17_cfg_t *cfg );
hallcurrent17_default_cfg
Click Default Configuration function.
err_t hallcurrent17_default_cfg ( hallcurrent17_t *ctx );
hallcurrent17_get_current
Hall Current 17 get current function.
err_t hallcurrent17_get_current ( hallcurrent17_t *ctx, float *current );
hallcurrent17_get_vout
Hall Current 17 get Vout function.
err_t hallcurrent17_get_vout ( hallcurrent17_t *ctx, float *adc_vout );
hallcurrent17_get_vref
Hall Current 17 get Vref function.
err_t hallcurrent17_get_vref ( hallcurrent17_t *ctx, float *adc_vref );
The initialization of SPI module and log UART. After driver initialization, the app sets the default configuration.
void application_init ( void )
{
log_cfg_t log_cfg; /**< Logger config object. */
hallcurrent17_cfg_t hallcurrent17_cfg; /**< Click config object. */
/**
* Logger initialization.
* Default baud rate: 115200
* Default log level: LOG_LEVEL_DEBUG
* @note If USB_UART_RX and USB_UART_TX
* are defined as HAL_PIN_NC, you will
* need to define them manually for log to work.
* See @b LOG_MAP_USB_UART macro definition for detailed explanation.
*/
LOG_MAP_USB_UART( log_cfg );
log_init( &logger, &log_cfg );
log_info( &logger, " Application Init " );
// Click initialization.
hallcurrent17_cfg_setup( &hallcurrent17_cfg );
HALLCURRENT17_MAP_MIKROBUS( hallcurrent17_cfg, MIKROBUS_1 );
if ( SPI_MASTER_ERROR == hallcurrent17_init( &hallcurrent17, &hallcurrent17_cfg ) )
{
log_error( &logger, " Communication init." );
for ( ; ; );
}
if ( HALLCURRENT17_ERROR == hallcurrent17_default_cfg ( &hallcurrent17 ) )
{
log_error( &logger, " Default configuration." );
for ( ; ; );
}
log_info( &logger, " Application Task " );
}
The demo application reads the current measurements [A] and displays the results. Results are being sent to the UART Terminal, where you can track their changes.
void application_task ( void )
{
static float current = 0.0;
if ( HALLCURRENT17_OK == hallcurrent17_get_current( &hallcurrent17, ¤t ) )
{
log_printf( &logger, " Current: %.3f [A]\r\n", current );
}
log_printf( &logger, " --------------------\r\n" );
Delay_ms ( 1000 );
}
This Click board can be interfaced and monitored in two ways:
- Application Output - Use the "Application Output" window in Debug mode for real-time data monitoring. Set it up properly by following this tutorial.
- UART Terminal - Monitor data via the UART Terminal using a USB to UART converter. For detailed instructions, check out this tutorial.
The complete application code and a ready-to-use project are available through the NECTO Studio Package Manager for direct installation in the NECTO Studio. The application code can also be found on the MIKROE GitHub account.