OSD Click demo application is developed using the NECTO Studio, ensuring compatibility with mikroSDK's open-source libraries and tools. Designed for plug-and-play implementation and testing, the demo is fully compatible with all development, starter, and mikromedia boards featuring a mikroBUS™ socket.
- Author : MikroE Team
- Date : Jan 2020.
- Type : SPI type
This demo performs basic OSD Click functionality - write text on screen.
- MikroSDK.Board
- MikroSDK.Log
- Click.OSD
osd_cfg_setup
Config Object Initialization function.
void osd_cfg_setup ( osd_cfg_t *cfg );
osd_init
Initialization function.
err_t osd_init ( osd_t *ctx, osd_cfg_t *cfg );
osd_default_cfg
Click Default Configuration function.
void osd_default_cfg ( osd_t *ctx );
osd_clear_display_memory
This function clears display memory.
void osd_clear_display_memory( osd_t *ctx );
osd_insert_custom_char
This function writes custom character.
void osd_insert_custom_char( osd_t *ctx, uint8_t chr_address, uint8_t custom_char );
osd_enable_video_buffer
This function enables video buffer.
void osd_enable_video_buffer( osd_t *ctx );
Device initialization.
void application_init ( void )
{
log_cfg_t log_cfg;
osd_cfg_t cfg;
/**
* Logger initialization.
* Default baud rate: 115200
* Default log level: LOG_LEVEL_DEBUG
* @note If USB_UART_RX and USB_UART_TX
* are defined as HAL_PIN_NC, you will
* need to define them manually for log to work.
* See @b LOG_MAP_USB_UART macro definition for detailed explanation.
*/
LOG_MAP_USB_UART( log_cfg );
log_init( &logger, &log_cfg );
log_info( &logger, " Application Init " );
// Click initialization.
osd_cfg_setup( &cfg );
OSD_MAP_MIKROBUS( cfg, MIKROBUS_1 );
osd_init( &osd, &cfg );
osd_default_cfg( &osd );
osd_clears_char_places( &osd, 0, 0, 16, 30 );
log_info( &logger, " Application Task " );
}
Write text on the screen, write character per 1 second in the first, seventh and fifteenth row of the screen.
void application_task ( void )
{
log_printf( &logger, "\r\n Writing characters on the screen...\r\n" );
for ( uint8_t cnt = 0; cnt < 30; cnt++ )
{
if ( HEADER_TEXT[ cnt ] != ' ' )
{
osd_write_character( &osd, 1, cnt, HEADER_TEXT[ cnt ] );
}
if ( MESSAGE_TEXT[ cnt ] != ' ' )
{
osd_write_character( &osd, 7, cnt, MESSAGE_TEXT[ cnt ] );
}
if ( FOOTER_TEXT[ cnt ] != ' ' )
{
osd_write_character( &osd, 14, cnt, FOOTER_TEXT[ cnt ] );
}
Delay_ms ( 1000 );
}
log_printf( &logger, " Clear display\r\n" );
osd_clears_char_places( &osd, 0, 0, 16, 30 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
}
This Click board can be interfaced and monitored in two ways:
- Application Output - Use the "Application Output" window in Debug mode for real-time data monitoring. Set it up properly by following this tutorial.
- UART Terminal - Monitor data via the UART Terminal using a USB to UART converter. For detailed instructions, check out this tutorial.
The complete application code and a ready-to-use project are available through the NECTO Studio Package Manager for direct installation in the NECTO Studio. The application code can also be found on the MIKROE GitHub account.