TempHum 25 Click demo application is developed using the NECTO Studio, ensuring compatibility with mikroSDK's open-source libraries and tools. Designed for plug-and-play implementation and testing, the demo is fully compatible with all development, starter, and mikromedia boards featuring a mikroBUS™ socket.
- Author : Stefan Filipovic
- Date : Apr 2024.
- Type : I2C type
This example demonstrates the use of TempHum 25 Click board by reading the temperature and humidity data.
- MikroSDK.Board
- MikroSDK.Log
- Click.TempHum25
temphum25_cfg_setup
Config Object Initialization function.
void temphum25_cfg_setup ( temphum25_cfg_t *cfg );
temphum25_init
Initialization function.
err_t temphum25_init ( temphum25_t *ctx, temphum25_cfg_t *cfg );
temphum25_read_serial_num
This function reads the 4-bytes unique serial number by using I2C serial interface.
err_t temphum25_read_serial_num ( temphum25_t *ctx, uint32_t *serial_num );
temphum25_start_measurement
This function starts the measurement by sending the selected measurement command.
err_t temphum25_start_measurement ( temphum25_t *ctx, uint16_t meas_cmd );
temphum25_read_measurement
This function reads the temperature and humidity measurements results.
err_t temphum25_read_measurement ( temphum25_t *ctx, float *temperature, float *humidity );
Initializes the driver, performs the device reset, reads and displays the sensor unique serial number, and then starts the measurements with 1 MPS.
void application_init ( void )
{
log_cfg_t log_cfg; /**< Logger config object. */
temphum25_cfg_t temphum25_cfg; /**< Click config object. */
/**
* Logger initialization.
* Default baud rate: 115200
* Default log level: LOG_LEVEL_DEBUG
* @note If USB_UART_RX and USB_UART_TX
* are defined as HAL_PIN_NC, you will
* need to define them manually for log to work.
* See @b LOG_MAP_USB_UART macro definition for detailed explanation.
*/
LOG_MAP_USB_UART( log_cfg );
log_init( &logger, &log_cfg );
log_info( &logger, " Application Init " );
// Click initialization.
temphum25_cfg_setup( &temphum25_cfg );
TEMPHUM25_MAP_MIKROBUS( temphum25_cfg, MIKROBUS_1 );
if ( I2C_MASTER_ERROR == temphum25_init( &temphum25, &temphum25_cfg ) )
{
log_error( &logger, " Communication init." );
for ( ; ; );
}
temphum25_reset_device ( &temphum25 );
uint32_t serial_num = 0;
if ( TEMPHUM25_OK == temphum25_read_serial_num ( &temphum25, &serial_num ) )
{
log_printf ( &logger, " Serial number: 0x%.8LX\r\n", serial_num );
}
temphum25_start_measurement ( &temphum25, TEMPHUM25_CMD_MEAS_CONT_REP_HIGH_MPS_1 );
log_info( &logger, " Application Task " );
}
Reads the temperature (degC) and the relative humidity (%RH) data and displays the results on the USB UART approximately once per second.
void application_task ( void )
{
float temperature = 0;
float humidity = 0;
if ( TEMPHUM25_OK == temphum25_read_measurement ( &temphum25, &temperature, &humidity ) )
{
log_printf ( &logger, " Temperature: %.2f degC\r\n", temperature );
log_printf ( &logger, " Humidity: %.2f %%RH\r\n\n", humidity );
Delay_ms ( 1000 );
}
}
This Click board can be interfaced and monitored in two ways:
- Application Output - Use the "Application Output" window in Debug mode for real-time data monitoring. Set it up properly by following this tutorial.
- UART Terminal - Monitor data via the UART Terminal using a USB to UART converter. For detailed instructions, check out this tutorial.
The complete application code and a ready-to-use project are available through the NECTO Studio Package Manager for direct installation in the NECTO Studio. The application code can also be found on the MIKROE GitHub account.