Description
Issue overview
"VRF Heat Pump Total Heating Rate" does not match the value of "TU1 VRF DX HEATING COIL:Heating Coil Heating Rate" / "VRF HEAT PUMP:VRF Heat Pump Indoor Unit Piping Correction for Heating"
diff = heat.pump.heating.rate - coil.heating.rate.div.piping ranges from -73.044 to 0, with a
percent diff = diff / heat.pump.heating.rate * 100 ranging from -1.03% to 0%
diff percent.diff
Min. :-73.044 Min. :-1.03251
1st Qu.: 0.000 1st Qu.: 0.00000
Median : 0.000 Median : 0.00000
Mean : -3.613 Mean :-0.05856
3rd Qu.: 0.000 3rd Qu.: 0.00000
Max. : 0.000 Max. : 0.00000
The following figure shows the timing of diff and percent diff
Defect file
The following zip file contains the idf and epw
defect_file.zip
This is the eplusout.csv output
eplusout.csv
Details
Some additional details for this issue (if relevant):
- Platform (Operating system, version)
- Version of EnergyPlus (if using an intermediate build, include SHA)
- Unmethours link or helpdesk ticket number
Checklist
Add to this list or remove from it as applicable. This is a simple templated set of guidelines.
- Defect file added (list location of defect file here)
- Ticket added to EnergyPlus Defect Complexity (Github Project)
- Pull request created (the pull request will have additional tasks related to reviewing changes that fix this defect)
Metadata
Metadata
Assignees
Labels
DefectIncludes code to repair a defect in EnergyPlusIncludes code to repair a defect in EnergyPlusDocumentationRelated primarily on the LaTeX-based EnergyPlus documentationRelated primarily on the LaTeX-based EnergyPlus documentation