Description
Issue overview
User file with hard-sized hot water coils fails with UA sizing error:
** Severe ** Autosizing of heating coil UA failed for Coil:Heating:Water "COILHEATING 23"
** ~~~ ** Bad starting values for UA
** ~~~ ** Lower UA estimate = 1.477957 W/m2-K (0.1% of Design Coil Load)
** ~~~ ** Upper UA estimate = 1477.957406 W/m2-K (100% of Design Coil Load)
** ~~~ ** Zone "ZN L01_ FRONT OFFICE N" coil sizing conditions (may be different than Sizing inputs):
** ~~~ ** Coil inlet air temperature = 16.600 C
** ~~~ ** Coil inlet air humidity ratio = 5.860E-003 kgWater/kgDryAir
** ~~~ ** Coil inlet air mass flow rate = 9.428277E-002 kg/s
** ~~~ ** Design Coil Capacity = 0.000 W
** ~~~ ** Design Coil Load = 1477.957 W
** ~~~ ** Coil outlet air temperature = 32.200 C
** ~~~ ** Coil outlet air humidity ratio = 1.514E-002 kgWater/kgDryAir
** ~~~ ** Inadequate water side capacity: in Plant Sizing for this hot water loop
** ~~~ ** increase design loop exit temperature and/or decrease design loop delta T
** ~~~ ** Plant Sizing object = HOTWATER LOOP
** ~~~ ** Plant design loop exit temperature = 60.000 C
** ~~~ ** Plant design loop delta T = 22.222 C
** Severe ** Developer Error: sizing of U-Factor Times Area Value [W/K] failed.
** ~~~ ** Occurs in Coil:Heating:Water COILHEATING 23
** Fatal ** Preceding water coil sizing errors cause program termination
Related to #11078
Tested the defect file with the fix in #11079. The simulation runs to completion. Not sure how to evaluate if it is a good solution for this case.
Operating System (Multiple choices)
Any
Operating System Version
any
Version of EnergyPlus
25.2.0-0200beacac
Unmethours link or helpdesk ticket number
Helpdesk ticket 16885
Defect file
EnergyPlusDevSupport\DefectFiles
Weather: Napa CA