HeatPump:PlantLoop:EIR:Heating with Setpoint control not operating #10831

@mjwitte

Description

@mjwitte

Issue overview

In a user file with HeatPump:PlantLoop:EIR:Heating, the heat pump was not operating with "Control Type" = Setpoint.
Adding a setpoint on the Source Side Outlet Node gets it to run.

The heatpump should check for a setpoint and either throw an error, or get the setpoint from the PlantLoop Loop Temperature Setpoint Node.

Details

Some additional details for this issue (if relevant):

  • Version of EnergyPlus 25.1.0-395539dc13
  • Direct email 11/20/2024

Checklist

Add to this list or remove from it as applicable. This is a simple templated set of guidelines.

  • Defect file added EnergyPlusDevSupport\DefectFiles
  • Ticket added to EnergyPlus Defect Complexity (Github Project)