Description
Issue overview
In a user file with HeatPump:PlantLoop:EIR:Heating, the heat pump was not operating with "Control Type" = Setpoint.
Adding a setpoint on the Source Side Outlet Node gets it to run.
The heatpump should check for a setpoint and either throw an error, or get the setpoint from the PlantLoop Loop Temperature Setpoint Node.
Details
Some additional details for this issue (if relevant):
- Version of EnergyPlus 25.1.0-395539dc13
- Direct email 11/20/2024