Skip to content

VRF System ReverseCycle Defrost Strategy - Missing EIR=f(T) curve #5596

@lymereJ

Description

@lymereJ

HVACTemplate:System:VRF doesn't assign a default curve for "Defrost Energy Input Ratio Modifier Function of Temperature Curve" when ReverseCycle is selected

When using the HVACTemplate:System:VRF object and selecting ReverseCycle as "Defrost Strategy", no default curves get assigned to "Defrost Energy Input Ratio Modifier Function of Temperature Curve" of the AirConditioner:VariableRefrigeratnFlow object after ExpandObject runs. The fact that the curve is missing was not triggering a Severe Error in EnergyPlus v8.4 but it does in EnergyPlus v8.5.

Workaround is to used the expidf output file and add an appropriate curve.

Details

  • Windows 10
  • EnergyPlus version 8.5

Metadata

Metadata

Assignees

Labels

AuxiliaryToolRelated to an auxiliary tool, not EnergyPlus itself (readvars, preprocessor, ep-launch, etc.)PriorityLowThis defect or feature has been declared low prioritySeverityMediumThis defect is medium severity, indicating moderate impact and generally no workaround available