AuxiliaryToolRelated to an auxiliary tool, not EnergyPlus itself (readvars, preprocessor, ep-launch, etc.)Related to an auxiliary tool, not EnergyPlus itself (readvars, preprocessor, ep-launch, etc.)PriorityLowThis defect or feature has been declared low priorityThis defect or feature has been declared low prioritySeverityMediumThis defect is medium severity, indicating moderate impact and generally no workaround availableThis defect is medium severity, indicating moderate impact and generally no workaround available
Description
HVACTemplate:System:VRF doesn't assign a default curve for "Defrost Energy Input Ratio Modifier Function of Temperature Curve" when ReverseCycle is selected
When using the HVACTemplate:System:VRF object and selecting ReverseCycle as "Defrost Strategy", no default curves get assigned to "Defrost Energy Input Ratio Modifier Function of Temperature Curve" of the AirConditioner:VariableRefrigeratnFlow object after ExpandObject runs. The fact that the curve is missing was not triggering a Severe Error in EnergyPlus v8.4 but it does in EnergyPlus v8.5.
Workaround is to used the expidf output file and add an appropriate curve.
Details
- Windows 10
- EnergyPlus version 8.5
Metadata
Metadata
Assignees
Labels
AuxiliaryToolRelated to an auxiliary tool, not EnergyPlus itself (readvars, preprocessor, ep-launch, etc.)Related to an auxiliary tool, not EnergyPlus itself (readvars, preprocessor, ep-launch, etc.)PriorityLowThis defect or feature has been declared low priorityThis defect or feature has been declared low prioritySeverityMediumThis defect is medium severity, indicating moderate impact and generally no workaround availableThis defect is medium severity, indicating moderate impact and generally no workaround available