Notifications
You must be signed in to change notification settings - Fork 5
/
settings.example.h
114 lines (92 loc) · 6.85 KB
/
settings.example.h
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
/* *** Default settings, adjustable in portal *** */
/* MQTT stuff */
const char* d_mqtt_host = "MQTT_SERV_IP"; // default MQTT host
const char* d_mqtt_topic_root = "pwutseltronics"; // default MQTT topic root
const char* d_notify_topic = "/debug/node_connect"; // default MQTT topic for messages regarding connection status
/* Influx stuff */
#define INFLUX // if defined, Influx related functionality is enabled
#ifdef INFLUX
const char* d_influx_topic = "/influx/metertrekker"; // default MQTT topic the influx lines will be published to
const char* d_influx_electricity_measurement = "electricity"; // default Influx measurement name for electricity data
const char* d_influx_gas_measurement = "gas"; // default Influx measurement name for gas data
#endif
/* Default telegram request interval and timeout */
const unsigned int d_interval = 15; // default telegram request interval in seconds
const unsigned int d_timeout = d_interval; // after d_timeout seconds of retrying to get a telegram, the portal will be started
/* *** Firmware configuration *** */
/* appended with the chipID and used as SSID, ArduinoOTA hostname and MQTT client ID */
const char* client_id = "Metertrekker";
/* To invert the RTS output logic, uncomment this line: */
#define RTS_INVERT_LOGIC // if defined, the RTS output logic is inverted
#ifdef RTS_INVERT_LOGIC
#define RTS_HIGH LOW
#define RTS_LOW HIGH
#else
#define RTS_HIGH HIGH
#define RTS_LOW LOW
#endif
#define RTS_PIN D3
/* Rx pin for SoftwareSerial */
#define RX_PIN RX
/* MQTT topic & InfluxDB column configuration */
typedef struct {
char ident[12];
int type;
char influx_column[24];
char mqtt_path[48];
char description[48];
} metricDef;
#define METRIC_TYPE_META 1
#define METRIC_TYPE_META_TEXT 2
#define METRIC_TYPE_FLOAT 11
#define METRIC_TYPE_TEXT 12
#define METRIC_TYPE_BARE 13
#define METRIC_TYPE_GAS 21
#define METRIC_TYPE_OTHER 99
/* Uncomment to enable metrics for three phase power: */
// #define THREE_PHASE // if defined, L2 and L3 metrics will be enabled
/* Metric and MQTT topic settings: comment a line to disable processing/publishing of the metric.
* Leaving the third entry (influx_column) empty will disable inclusion in the influx line, if influx functionality is enabled */
metricDef metricDefs[] = { // metric metadata and destination column/topic lookup table
//{ "OBIS ref.", METRIC_TYPE_CONSTANT, "influx col.", "MQTT path", "description (only for serial debug output)" },
{ "1-3:0.2.8", METRIC_TYPE_META, "", "", "SMR protocol version" },
{ "0-0:1.0.0", METRIC_TYPE_META, "timestamp", "", "telegram timestamp" },
{ "0-0:96.1.1", METRIC_TYPE_META_TEXT, "meter_sn", "", "meter serial number" },
{ "1-0:1.8.1", METRIC_TYPE_FLOAT, "delivered_low", "/energy/mains/reading/delivered/low", "total delivered energy (low tariff)" },
{ "1-0:1.8.2", METRIC_TYPE_FLOAT, "delivered_high", "/energy/mains/reading/delivered/high", "total delivered energy (high tariff)" },
{ "1-0:2.8.1", METRIC_TYPE_FLOAT, "redelivered_low", "/energy/mains/reading/redelivered/low", "total redelivered (low tariff)" },
{ "1-0:2.8.2", METRIC_TYPE_FLOAT, "redelivered_high", "/energy/mains/reading/redelivered/high", "total redelivered (high tariff)" },
{ "0-0:96.14.0", METRIC_TYPE_BARE, "tariff", "/energy/mains/reading/tariff", "tariff" },
{ "1-0:1.7.0", METRIC_TYPE_FLOAT, "P_total", "/energy/mains/power/total", "total power" },
{ "1-0:2.7.0", METRIC_TYPE_FLOAT, "P_total_redelivery", "/energy/mains/power/total_redelivery", "total redelivery power" },
{ "1-0:21.7.0", METRIC_TYPE_FLOAT, "P_L1", "/energy/mains/power/L1", "L1 power" },
{ "1-0:22.7.0", METRIC_TYPE_FLOAT, "P_L1_redelivery", "/energy/mains/power/L1_redelivery", "L1 redelivery power" },
{ "1-0:32.7.0", METRIC_TYPE_FLOAT, "V_L1", "/energy/mains/voltage/L1", "L1 voltage" },
{ "1-0:31.7.0", METRIC_TYPE_FLOAT, "I_L1", "/energy/mains/current/L1", "L1 current" },
#ifdef THREE_PHASE
{ "1-0:41.7.0", METRIC_TYPE_FLOAT, "P_L2", "/energy/mains/power/L2", "L2 power" },
{ "1-0:42.7.0", METRIC_TYPE_FLOAT, "P_L2_redelivery", "/energy/mains/power/L2_redelivery", "L2 redelivery power" },
{ "1-0:52.7.0", METRIC_TYPE_FLOAT, "V_L2", "/energy/mains/voltage/L2", "L2 voltage" },
{ "1-0:51.7.0", METRIC_TYPE_FLOAT, "I_L2", "/energy/mains/current/L2", "L2 current" },
{ "1-0:61.7.0", METRIC_TYPE_FLOAT, "P_L3", "/energy/mains/power/L3", "L3 power" },
{ "1-0:62.7.0", METRIC_TYPE_FLOAT, "P_L3_redelivery", "/energy/mains/power/L3_redelivery", "L3 redelivery power" },
{ "1-0:72.7.0", METRIC_TYPE_FLOAT, "V_L3", "/energy/mains/voltage/L3", "L3 voltage" },
{ "1-0:71.7.0", METRIC_TYPE_FLOAT, "I_L3", "/energy/mains/current/L3", "L3 current" },
#endif
{ "0-1:24.1.0", METRIC_TYPE_BARE, "", "", "gas meter device type" },
{ "0-1:96.1.0", METRIC_TYPE_META_TEXT, "gas_meter_sn", "", "gas meter serial number" },
{ "0-1:24.2.1", METRIC_TYPE_GAS, "gas_reading", "/energy/gas/reading", "gas meter last reading" },
{ "0-0:96.7.21", METRIC_TYPE_BARE, "failures", "/energy/mains/report/powerfailures", "power failures" },
{ "0-0:96.7.9", METRIC_TYPE_BARE, "long_failures", "/energy/mains/report/powerfailures_long", "long power failures" },
{ "1-0:99.97.0", METRIC_TYPE_OTHER, "failure_log", "/energy/mains/report/powerfailure_details", "power failure event log" },
{ "1-0:32.32.0", METRIC_TYPE_BARE, "L1_sags", "/energy/mains/report/voltage_sags/L1", "L1 voltage sags" },
{ "1-0:32.36.0", METRIC_TYPE_BARE, "L1_swells", "/energy/mains/report/voltage_swells/L1", "L1 voltage swells" },
#ifdef THREE_PHASE
{ "1-0:52.32.0", METRIC_TYPE_BARE, "L2_sags", "/energy/mains/report/voltage_sags/L2", "L2 voltage sags" },
{ "1-0:52.36.0", METRIC_TYPE_BARE, "L2_swells", "/energy/mains/report/voltage_swells/L2", "L2 voltage swells" },
{ "1-0:72.32.0", METRIC_TYPE_BARE, "L3_sags", "/energy/mains/report/voltage_sags/L3", "L3 voltage sags" },
{ "1-0:72.36.0", METRIC_TYPE_BARE, "L3_swells", "/energy/mains/report/voltage_swells/L3", "L3 voltage swells" },
#endif
{ "0-0:96.13.0", METRIC_TYPE_TEXT, "message", "/energy/mains/message", "text message" }, // text message
{ "0-0:96.13.1", METRIC_TYPE_TEXT, "message", "/energy/mains/message", "text message" } // text message
};