You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
I am using the current master branch or the latest release. Please indicate:
Describe the Bug
As of today, April 9, 2025, DEA technology_datasheet_for_energy_storage version 9 contains an error in the FOM values for pit thermal energy storages. In version 9, the FOM is increased by a factor of 1,000 compared to version 8. However, the tech brief (https://ens.dk/media/6445/download) that outlines the changes from version 8 to 9 clearly indicates that the FOM should decrease by 19%. As a workaround, I manually adjusted the FOM in the compile_cost_assumptions.py to the correct unit (€/MWhCapacity/year).