You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Recording segments seem to be aware of non zero start times. However, when in an analyzer or sorting, times always assume the recording starts at time 0. This can be checked in the GUI for example.
I believe this does not create any main issue as the analyzer seems consistent with itself. However, this is very unintuitive and maybe not expected ?