Notifications
You must be signed in to change notification settings - Fork 140
IBeam Configuration
IBeam can be configured in many ways to suit your specific needs. This section lists all possible configuration settings and discusses some of them in more detail.
To facilitate custom usage and become more future-proof, IBeam expects the following environment variables altering its behaviour:
| Variable name | Default value | Description |
|---|---|---|
IBEAM_INPUTS_DIR |
/srv/inputs/ | Directory path of Inputs Directory. |
IBEAM_OUTPUTS_DIR |
../outputs | Directory path of Outputs Directory. |
IBEAM_GATEWAY_DIR |
None | Path to the root of the IBKR Gateway. |
IBEAM_CHROME_DRIVER_PATH |
None | Path to the Chrome Driver executable file. |
IBEAM_GATEWAY_STARTUP |
20 | How many seconds to wait for the Gateway to respond after its startup. |
IBEAM_GATEWAY_PROCESS_MATCH |
ibgroup.web.core.clientportal.gw.GatewayStart | The gateway process' name to match against. |
IBEAM_MAINTENANCE_INTERVAL |
60 | How many seconds between each maintenance. |
IBEAM_SPAWN_NEW_PROCESSES |
False | Whether new processes should be spawned for each maintenance. |
IBEAM_LOG_LEVEL |
INFO | Verbosity level of the logger used. |
IBEAM_LOG_TO_FILE |
True | Whether logs should also be saved to a file. |
IBEAM_REQUEST_RETRIES |
1 | How many times to reattempt a request to the gateway. |
IBEAM_REQUEST_TIMEOUT |
15 | How many seconds to wait for a request to complete. |
| Variable name | Default value | Description |
|---|---|---|
IBEAM_GATEWAY_BASE_URL |
https://localhost:5000 | Base URL of the gateway. |
IBEAM_ROUTE_AUTH |
/sso/Login?forwardTo=22&RL=1&ip2loc=on | Gateway route with authentication page. |
IBEAM_ROUTE_USER |
/v1/api/one/user | Gateway route with user information. |
IBEAM_ROUTE_VALIDATE |
/v1/portal/sso/validate | Gateway route with validation call. |
IBEAM_ROUTE_REAUTHENTICATE |
/v1/portal/iserver/reauthenticate?force=true | Gateway route with reauthentication call. |
IBEAM_ROUTE_AUTH_STATUS |
/v1/api/iserver/auth/status | Gateway route with authentication status call. |
IBEAM_ROUTE_TICKLE |
/v1/api/tickle | Gateway route with tickle call. |
| Variable name | Default value | Description |
|---|---|---|
IBEAM_USER_NAME_EL_ID |
user_name | HTML element id containing the username input field. |
IBEAM_PASSWORD_EL_ID |
password | HTML element id containing the password input field. |
IBEAM_SUBMIT_EL_ID |
submitForm | HTML element id containing the submit button. |
IBEAM_ERROR_EL_ID |
ERRORMSG | HTML element id containing the submit button. |
IBEAM_SUCCESS_EL_TEXT |
Client login succeeds | HTML element text indicating successful authentication. |
IBEAM_OAUTH_TIMEOUT |
15 | How many seconds to wait for the OAuth login request to complete. |
IBEAM_PAGE_LOAD_TIMEOUT |
15 | How many seconds to wait for the login page to load. |
IBEAM_ERROR_SCREENSHOTS |
False | Whether to save login page screenshots on error. |
IBEAM_MAX_FAILED_AUTH |
5 | Maximum number of failed authentication attempts. |
IBEAM_MAX_IMMEDIATE_ATTEMPTS |
10 | Maximum number of immediate retries upon detecting an error message. |
| Variable name | Default value | Description |
|---|---|---|
IBEAM_TWO_FA_EL_ID |
twofactbase | HTML element check for if Gateway will require 2FA authentication. |
IBEAM_TWO_FA_INPUT_EL_ID |
chlginput | HTML element to input 2FA code into |
IBEAM_TWO_FA_HANDLER |
None | Which 2FA handler should be used to acquire the code. |
IBEAM_STRICT_TWO_FA_CODE |
True | Whether to ensure only 2FA code made of 6 digits can be used. |
Upon starting the Gateway, IBeam will begin to repeatedly attempt to communicate with it every 1 second until the Gateway is ready or the startup timeout set by IBEAM_GATEWAY_STARTUP is reached.
When monitoring the Gateway, IBeam will send it different requests that check for its health and authentication status. These requests may take long or fail at first attempt on some systems.
IBEAM_REQUEST_RETRIES and IBEAM_REQUEST_TIMEOUT allow you to set how many times IBeam will retry each such internal request to the Gateway, and how many seconds to wait for these to complete
On some systems, the Gateway takes longer than usual to load the HTML page IBeam uses to authenticate. IBEAM_PAGE_LOAD_TIMEOUT defines how long IBeam will wait for the Gateway to load this page.
Once the page is loaded, IBeam will input the credentials and submit them, waiting for an update on the web page indicating that the request has completed. IBEAM_OAUTH_TIMEOUT defines how long IBeam will wait for the authentication request to complete.
Upon observing a failure in the authentication request on the web page, IBeam will immediately attempt to reauthenticate. IBEAM_MAX_IMMEDIATE_ATTEMPTS defines the limit after which IBeam will stop authentication attempts and report a failure in authentication.
As of writing this, IBKR performs a 24-hour lock-out on an account upon 10 consecutive unsuccessful login attempts. Any successful login is meant to reset this counter.
To prevent this lock-out from happening, IBeam will count the amount of consecutive failed attempts and shut down if authentication fails too many times. The environment variable IBEAM_MAX_FAILED_AUTH defines the maximum number of failed authentication attempts that IBeam will allow. To disable this functionality, set this environment variable to a very large number.
IBeam by default logs all information using a Python standard library's logging module, through a custom logger called 'ibeam'. The default log level is INFO, which you can set to DEBUG using the IBEAM_LOG_LEVEL variable.
All logs are saved to a file in the Outputs Directory. This behaviour can be disabled by setting IBEAM_LOG_TO_FILE to False.
Additionally, you can set IBEAM_ERROR_SCREENSHOTS to True in order for IBeam to attempt to save a screenshot upon encountering an error during authentication. All screenshots are saved in the Outputs Directory.
Once the Gateway is started and authenticated, IBeam will begin the maintenance, during which it will repeatedly check the health and authentication status of the Gateway and take appropriate actions if needed. The interval for this maintenance is set by IBEAM_MAINTENANCE_INTERVAL variable.
Learn about Gateway Configuration
See any error on this page? Create an Issue and let us know.