#include "thalesremoteconnection.h"
#include "thalesremotescriptwrapper.h"
int main(int argc, char *argv[]) {
ZenniumConnection ZenniumConnection;
ZenniumConnection.connectToTerm("localhost", "ScriptRemote");
ThalesRemoteScriptWrapper zahnerZennium(&ZenniumConnection);
zahnerZennium.forceThalesIntoRemoteScript();
/*
* Settings on the FRA mode are only allowed to be changed if the FRA mode is deactivated.
*/
zahnerZennium.disableFraMode();
zahnerZennium.setFraVoltageMinimum(0);
zahnerZennium.setFraVoltageMaximum(18);
zahnerZennium.setFraCurrentMinimum(0);
zahnerZennium.setFraCurrentMaximum(220);
zahnerZennium.setFraVoltageInputGain(18.0/5.0);
zahnerZennium.setFraVoltageOutputGain(18.0/5.0);
zahnerZennium.setFraCurrentInputGain(-220.0/5.0);
zahnerZennium.setFraCurrentOutputGain(-220.0/5.0);
zahnerZennium.setFraPotentiostatMode(PotentiostatMode::GALVANOSTATIC);
zahnerZennium.enableFraMode();
zahnerZennium.setCurrent(0);
/*
* Now the device which is analog controlled by FRA should be switched on with its own interface.
* Then you can measure EIS via FRA like with the internal potentiostat.
*/
for (double i = 1; i < 8 ; i += 1) {
zahnerZennium.setCurrent(i);
std::this_thread::sleep_for(std::chrono::milliseconds(200));
std::cout << zahnerZennium.getPotential() << std::endl;
std::cout << zahnerZennium.getCurrent() << std::endl;
}
zahnerZennium.setEISNaming(NamingRule::COUNTER);
zahnerZennium.setEISCounter(1);
zahnerZennium.setEISOutputPath("c:\\thales\\temp\\test1");
zahnerZennium.setEISOutputFileName("delta");
zahnerZennium.setAmplitude(0.5);
zahnerZennium.setCurrent(5);
zahnerZennium.setLowerFrequencyLimit(0.1);
zahnerZennium.setStartFrequency(10);
zahnerZennium.setUpperFrequencyLimit(100);
zahnerZennium.setLowerNumberOfPeriods(3);
zahnerZennium.setLowerStepsPerDecade(5);
zahnerZennium.setUpperNumberOfPeriods(20);
zahnerZennium.setUpperStepsPerDecade(5);
zahnerZennium.setScanDirection(ScanDirection::START_TO_MAX);
zahnerZennium.setScanStrategy(ScanStrategy::SINGLE_SINE);
zahnerZennium.measureEIS();
/*
* Now switch off the device, which is controlled analog with FRA via its own interface.
*/
zahnerZennium.disableFraMode();
ZenniumConnection.disconnectFromTerm();
std::cout << "finish" << std::endl;
return 0;
}