Skip to content
This repository has been archived by the owner on Apr 10, 2023. It is now read-only.

Catastrophic failure mode possible on different hardware #52

Open
ctech4285 opened this issue Apr 14, 2017 · 1 comment
Open

Catastrophic failure mode possible on different hardware #52

ctech4285 opened this issue Apr 14, 2017 · 1 comment

Comments

@ctech4285
Copy link
Contributor

Force 1 second delay when power stage misfires. Misfire = main capacitor is not discharged after firing

It is possible on different hardware that the holding current is reached. Via the cathode pull down resistor on the power stage
It cause the Thyristor to stay on for up to 1 second. Subsequently firing its lower pair will cause the two thyristors to eat to much power and fail as short.

I'll take care of it before we change out the thyristors for the next rev

@pavel-kirienko
Copy link
Member

Please keep us posted. Let me know if any software changes are necessary.