Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathiaq_calc.py
38 lines (30 loc) · 1.1 KB
/
iaq_calc.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
humidity = 40
gas = 40000
# Set the humidity baseline to 40%, an optimal indoor humidity.
humidity_baseline = 40.0
# This sets the balance between humidity and gas reading in the
# calculation of air_quality_score (25:75, humidity:gas)
humidity_weighting = 0.25
gas_weighting = 0.75
gas_reference = 40000
hum_reference = 40
gas_lower_limit = 5000
gas_upper_limit = 50000
if humidity >= 38 and humidity <= 42:
humidity_score = humidity_weighting * 100
else:
if humidity < 38:
humidity_score = humidity_weighting / hum_reference * humidity * 100;
else:
humidity_score = ((-humidity_weighting / (100 - hum_reference) * humidity) + 0.416666) * 100;
print("Humidity Score: ", humidity_score)
gas_score = (gas_weighting / (gas_upper_limit - gas_lower_limit) * gas_reference - (gas_lower_limit * (gas_weighting / (gas_upper_limit - gas_lower_limit)))) * 100.00
if gas_score > 75:
gas_score = 75
if gas_score < 0:
gas_score = 0
print("GasScore: ", gas_score)
air_quality_score = humidity_score + gas_score
print("IAQ: ", air_quality_score)
score = (100-air_quality_score)*5
print(score)