Right now the QuantityModel
(as output by the fitting machinery) only accepts inputs with the same units as the spectrum.spectral_axis that was used to create it. It would be nice if it also recognized spectral equivalencies - i.e., if you give a continuum model, say, a GHz
quantity, it should know to convert it if the input to the model is angstrom
, using the spectral
equivalencies provided by astropy.