Notifications
You must be signed in to change notification settings - Fork 191
Description
Your idea
[BEP Proposal] ZTE-based fMRI extension
Proposal summary
We propose a new BIDS Extension Proposal (BEP) to support Zero Echo Time (ZTE)-based
functional MRI (fMRI) acquisitions.
This extension focuses on explicitly recording how ZTE-based fMRI data were acquired
and how they were reconstructed, without prescribing reconstruction algorithms or
requiring access to raw k-space data. The goal is to improve data provenance,
interpretability, and cross-study comparability, while remaining fully backwards
compatible with existing BIDS datasets and tools.
Defined scope
In scope
- Functional (time-series) ZTE-based MRI acquisitions
- ZTE-derived fMRI sequence families (e.g., ZTE, SORDINO, MB-SWIFT)
- Metadata describing:
- How the data were acquired (acquisition strategy, trajectory, key parameters)
- Which reconstruction approach and software were used
- Minimal, human- and machine-readable reconstruction descriptors
- An extensible framework that can accommodate additional ZTE-based fMRI variants
not yet explicitly listed
Out of scope
- Definition or standardization of reconstruction algorithms
- Raw k-space reconstruction requirements
- Vendor- or site-specific reconstruction pipelines
- Derivatives specification
Proposed data organization
- Data type:
func - Proposed suffix:
zte(tentative) - Example filename:
sub-01_task-rest_run-01_zte.nii.gzsub-01_task-rest_run-01_zte.json
The suffix is intentionally distinct from bold to avoid implying T2*-weighted
contrast. The final suffix selection should be aligned with community feedback.
Metadata fields
Standard BIDS fields (reused)
RepetitionTime(s)EchoTime(s)FlipAngle(deg)MRAcquisitionType("3D")ManufacturerSequenceName
Proposed ZTE extension fields
The following fields are proposed as ZTE-specific metadata to record
radial and non-radial sampling characteristics and to document the
reconstruction approaches applied to ZTE-based fMRI data, supporting
interpretability and cross-study comparability:
ZTETechnique: sequence family (e.g.,ZTE,SORDINO,MB-SWIFT)ZTETrajectoryType: trajectory type (e.g.,radial,spiral,cones,cartesian)ZTEReadoutPoints: number of readout samples per spokeZTEProjections: number of projections/spokes per frameZTEOverSampling: oversampling factorZTEEffectiveBandwidth: effective bandwidth (Hz)ZTEAcqDelayTotal: acquisition delay (us)ZTEUnderSampling: under-sampling factorZTEReceiverChannels: number of receiversReconMatrix: reconstruction matrixFieldOfView: FOV in mmSpatialResolution: nominal resolution in mmSliceOrientation: slice orientation labelsReadoutOrientation: readout orientation labelsReconstructionMethod: method or filter used for reconstructionReconstructionType: "vendor", "custom", or "unknown"ReconstructionSoftware: software nameReconstructionSoftwareVersion: software versionReconstructionDescription: brief free-text description of the approach
These fields are intended to be machine-readable and aligned with existing
parameter names to minimize ambiguity.
Use cases
- Sharing and archiving ZTE-based fMRI datasets in a BIDS-compliant manner
- Transparently documenting acquisition and reconstruction provenance for
ZTE-based fMRI studies - Enabling correct interpretation and comparison of ZTE-based fMRI data across
sites, vendors, and studies - Supporting tool developers and data users who need to understand how ZTE-based
fMRI data were generated, without requiring reconstruction reproducibility
Example
The example below illustrates how a ZTE-based fMRI dataset can document both
how the data were acquired and how they were reconstructed, without
prescribing or standardizing reconstruction algorithms.
This example is provided for illustration only. The listed fields are not
intended to be exhaustive or mandatory.
{
"RepetitionTime": 0.05,
"EchoTime": 0.0,
"FlipAngle": 2.0,
"MRAcquisitionType": "3D",
"Manufacturer": "Bruker",
"SequenceName": "sordino",
"ZTETechnique": "SORDINO",
"ZTETrajectoryType": "radial",
"ZTEReadoutPoints": 256,
"ZTEProjections": 12000,
"ZTEOverSampling": 2.0,
"ZTEEffectiveBandwidth": 100000.0,
"ReconstructionMethod": "RecoRegridNFilter",
"ReconstructionType": "vendor",
"ReconstructionSoftware": "ParaVision",
"ReconstructionSoftwareVersion": "360.3.5",
"ReconstructionDescription": "Vendor-provided Filters for non-Cartesian reconstruction"
}In this example:
- Acquisition-related fields describe how k-space data were sampled and how the
ZTE-based fMRI time-series was acquired. - Reconstruction-related fields record which reconstruction approach and
software were used to generate the final images.
These fields record what was done, but do not define or prescribe how
reconstruction should be performed.
Community input and open participation
While this proposal includes example acquisition and reconstruction metadata for
selected ZTE-based fMRI sequences (e.g., ZTE and SORDINO), a complete and
community-agreed parameter set is not yet defined for all ZTE-based fMRI
implementations.
In particular, sequence families such as MB-SWIFT, as well as other ZTE-derived
or related fMRI implementations not explicitly listed here, may require additional
or sequence-specific metadata.
Input and contributions from the broader ZTE-based fMRI community are explicitly
welcomed to help identify missing parameters, refine existing fields, and ensure
that the extension remains inclusive and extensible.
Current status
A draft specification document is under active development. This issue is intended
to gauge community interest, collect early feedback, and identify potential
contributors before proceeding to a formal BEP submission.