Releases: bigladder/HPWHsim
Releases · bigladder/HPWHsim
Version 1.12.4
CAHP120 Model with correct resistance element sizes
Version 1.12.3
Correctly tuned CAHP 120 model
Version 1.12.2
Allow force the changing of tank sizes for all models
Version 1.12.1
Fix condensity sum bug for in progress CAHP preset
Version 1.12.0
- Tank sizes fixed for unitary HPWH's
- Function signatures rewrote with defaults
- Secret new model CAHP 120 (still in development)
Version 1.11.1
Fix bug where bottom node would exceed setpoint if the rest of the tank was above setpoint.
Version 1.11.0
-
New DR Signals (not backwards compatible):
- DR_LOC (1)
- DR_LOR (2)
- DR_TOO (4)
- DR_TOT (8)
- Supports combining with bitwise OR
- DR_TOO | DR_TOT is conflicting, the way it is set up is that DR_TOT will dominate.
-
Add Sanden 120 gallon preset
-
Fix bug where 2 ER elements could run at once.
-
Fix bug where a lockout heat source could run an already engaged heat source.
Version 1.10.3
- Fix inversion mixing bug.
- Conduction stability error now fatal.
Version 1.10.2
- New Colmac Performance Maps for CxV-5 and CxA series from data submitted to the CEC.
- Nyle logic changed to allow operation as a swing tank with a 15 degree temperature lift.
- Colmac systems given same treatment
- Additional tests to give yearly performance estimates.
- Speed improvements to testing.
Version 1.10.1
- Update to Rheem Premium and Builder model presets