Zephyr EC Battery

[TOC]

Overview

The battery is the rechargeable internal power source for the device.

Kconfig Options

CONFIG_PLATFORM_EC_BATTERY enables battery support in the EC application. Refer to Kconfig.battery for all sub-options controlling battery behavior.

Devicetree Nodes

How to enable batteries on a board

Enable battery feature configs

Add battery configs to either the program.conf or project.conf file for your project.

Example:

# Battery
CONFIG_PLATFORM_EC_BATTERY=y
CONFIG_PLATFORM_EC_BATTERY_SMART=y
CONFIG_PLATFORM_EC_BATTERY_FUEL_GAUGE=y
CONFIG_PLATFORM_EC_BATTERY_CUT_OFF=y
CONFIG_PLATFORM_EC_BATTERY_HW_PRESENT_CUSTOM=y
CONFIG_PLATFORM_EC_BATTERY_REVIVE_DISCONNECT=y

Add devicetree nodes

Add batteries devicetree node to the board overlay's root node

Example:

  batteries {
		default_battery: vendor_part {
			compatible = "vendor,part";
		};
		vendor2_part2 {
			compatible = "vendor2,part2";
		};
   };

Here vendor_part will be the default battery type. If this node label is present in the overlay, the DEFAULT_BATTERY_TYPE is set in the battery shim code with the labeled battery type. The vendor and part references must match an existing battery defined in battery bindings directory.

Add the battery present GPIO node as a child of named-gpios

Example:

named-gpios {
	compatible = "named-gpios";
	...
	...
	ec_batt_pres_odl {
		gpios = <{SOME GPIO} GPIO_INPUT>;
	};
	...
	...
};

See the Zephyr gpios doc for more information on the named-gpios node.

Add a battery node as a child of named-i2c-ports

Example:

named-i2c-ports {
	compatible = "named-i2c-ports";
	...
	...
	battery {
		i2c-port = <{i2c_phandle}>;
		remote-port = <{I2C_PASSTHRU-PORT-NUMBER}>;
		enum-names = "I2C_PORT_BATTERY";
	};
	...
	...
}

Most battery fuel gauges support operation of only 100 KHz on the I2C bus, so ensure the clock-frequency for the bus is set appropriately. See the Zephyr I2C doc for more information on the named-i2c-ports node.

Refer to the cros-ec-i2c-port-base.yaml child-binding file for details about each property.

Example CL enabling batteries on a board

How to create a new battery

description: "VENDOR PART"
compatible: "vendor,part"

include: battery-smart.yaml

properties:
   enum-name:
      type: string
      default: "vendor,part"

Refer to the vendor's datasheet to set all the fuel gauge and battery properties required in the vendor,part.yaml file.

Example CL adding a new battery

Board Specific Code

Enabling CONFIG_PLATFORM_EC_BATTERY_PRESENT_CUSTOM requires the board to provide a custom battery_is_present() function.

Threads

Battery support alone does not enable any threads. However, the charger task requires the battery module for correct operation.

Testing and Debugging

EC Console Commands

battery

The battery EC console command may be invoked to check battery information on a flashed board.

Example output of uart:~$ battery:

Status:    0x00e0 FULL DCHG INIT
Param flags:00000002
Temp:      0x0b69 = 292.1 K (19.0 C)
V:         0x2ffc = 12284 mV
V-desired: 0x0000 = 0 mV
I:         0x0000 = 0 mA
I-desired: 0x0000 = 0 mA
Charging:  Not Allowed
Charge:    96 %
  Display: 98.7 %
Manuf:     LGC
Device:    AC17A8M
Chem:      LION
Serial:    0xd3b3
V-design:  0x2d1e = 11550 mV
Mode:      0x6001
Abs charge:73 %
Remaining: 3901 mAh
Cap-full:  4074 mAh
  Design:  5360 mAh
Time-full: 0h:0
  Empty:   0h:0
full_factor:0.97
shutdown_soc:4 %

pwr_avg

The pwr_avg EC console command logs the battery charging rate by querying the battery fuel gauge driver.

Example output of uart:~$ pwr_avg:

Charging

mv = 13073
ma = 439
mw = 573

Discharging

mv = 12824
ma = -146
mw = -1872

Note: A fully charged board may report ma = 0 and mw = 0 average rates.

chgstate

The chgstate EC console command may be invoked to debug and manipulate machine charging state.

Example output of uart:~$ chgstate:

state = charge
ac = 1
batt_is_charging = 1
chg.*:
	voltage = 13200mV
	current = 0mA
	input_current = 3000mA
	status = 0xc010
	option = 0x2830004
	flags = 0x0
batt.*:
	temperature = 26C
	state_of_charge = 100%
	voltage = 13037mV
	current = 0mA
	desired_voltage = 0mV
	desired_current = 0mA
	flags = 0x2
	remaining_capacity = 4436mAh
	full_capacity = 4436mAh
	is_present = YES
requested_voltage = 0mV
requested_current = 0mA
chg_ctl_mode = 0
manual_voltage = -1
manual_current = -1
user_current_limit = -1mA
battery_seems_to_be_dead = 0
battery_seems_to_be_disconnected = 0
battery_was_removed = 0
debug output = off

AP Console Commands (ectool)

chargestate

The chargestate ectool command may be invoked to debug and manipulate machine charging state.

Usage output of uart: # ectool chargestate:

Usage:
  chargestate show                  - show current state
  chargestate param NUM [VALUE]     - get/set param NUM
  chargestate param help            - show known param NUMs