Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

SETPOT: Grid of insufficient extent #103

Open
mtabulo opened this issue Feb 25, 2023 · 2 comments
Open

SETPOT: Grid of insufficient extent #103

mtabulo opened this issue Feb 25, 2023 · 2 comments

Comments

@mtabulo
Copy link

mtabulo commented Feb 25, 2023

I was running a rwfnestimate calculation for Barium, using a CSF of:
[Xe] 6s(2,)
[Xe] 6s(1,
)5d(1,)
[Xe] 5d(2,
)

Double excitations and with the active orbitals:
10s,9p,9d,7f,7g,7h,7i

I received the error:
SETPOT: Grid of insufficient extent.

Wondering if this is a limitation of the program/calculations, or if it's a physical hardware limitation of my computer?

I can increase the principle quantum number above 10, so I don't think that's the issue, but I can't seem to increase the orbital angular momentum number past 5 (h).

@s-rathi
Copy link

s-rathi commented Mar 27, 2023

@mtabulo You can try changing the grid parameters. How to change the parameters is explained in GRASP2018 manual.

@JonnoDean
Copy link

JonnoDean commented Sep 20, 2024

I've encountered this issue too, whilst attempting calculations on an O 2- ion. Electron config: [He]2s2 2p6.

The single config calculations work with a non-default grid of NNP = 1990 points. This also works for the 3s expansion of the active set. However, expansions passed the 3s orbital fail.

Even extending NNP to a ridiculous 59000 (100x greater than default) doesn't resolve this issue. I've tried a wide range of grid parameters and none seem to work.