Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

accuracy comparison number wrong? #5

Open
rgeirhos opened this issue Jan 24, 2020 · 0 comments
Open

accuracy comparison number wrong? #5

rgeirhos opened this issue Jan 24, 2020 · 0 comments

Comments

@rgeirhos
Copy link

rgeirhos commented Jan 24, 2020

In https://distill.pub/2019/advex-bugs-discussion/response-2/ it is stated that "testing on the CIFAR test set incurs an accuracy of 23.5% (out of 88%)."

When compared to Table 1 of the original paper (https://arxiv.org/pdf/1905.02175.pdf), it should be "out of 63%" if I'm not mistaken: the 88% refers to the accuracy of a model trained on ImageNet_R rather than CIFAR-10.

Furthermore, at the bottom of the page, the github issue link leads to a 404 error: https://github.com/distillpub/post--ilyas-response-2/issues/new which could be fixed by updating the link and instead referring to https://github.com/distillpub/post--ilyas-responses/issues