Max31856 - cold-junction compensated thermocouple to digital converter

The Max31856 device is a SPI interface cold-junction compensated thermocouple to digital converter.

Illustration of wiring from a Raspberry Pi device

Note: ThermocoupleType.K is configured for a K type thermocouple if you want to use a B,E,J,K,N,R,S, or T simply change the K to the thermocouple type of your choosing.

Documentation

Usage

The Max31856.samples file contains a sample usage of the device. Note that this reads two temperatures. One is a connected thermocouple reading which can be read using the TryGetTemperature command and the other is the temperature of the device itself which can be read using the GetColdJunctionTemperature command. The Cold Junction Temperature is used internally to increase the accuracy of the thermocouple but can also be read if you find a use for it.

Create a new SpiConnectionSettings Class if using a Raspberry Pi do not change these settings.

SpiConnectionSettings settings = new(0, 0)
{
    ClockFrequency = Max31856.SpiClockFrequency,
    Mode = Max31856.SpiMode,
    DataFlow = 0
};

Create a new SpiDevice with the settings from above. Then create a new Max31856 device with the SpiDevice as well as the correct ThermocoupleType (see note below)

using SpiDevice device = SpiDevice.Create(settings);
using Max31856 sensor = new(device, ThermocoupleType.K);

Now read the temperature from the device. Using the UnitsNet nuget you can see the units of your choosing. In this example you chan changeDegreesFahrenheit to DegreesCelsius or any other unit by changing .GetTemperature().DegreesFahrenheit to another unit of your choice.

while (true)
{
    Temperature tempColdJunction = sensor.GetColdJunctionTemperature();
    Console.WriteLine($"Temperature: {tempColdJunction}");
    Thread.Sleep(2000);
}