Build: https://dev.azure.com/dnceng-public/public/_build/results?buildId=603897
Build error leg or test failing: GC/API/GCHandleCollector/Usage/Usage.sh
Pull request: #81291
Error Message
Fill the error message using known issues guidance.
{
"ErrorMessage": "System.InvalidOperationException: Handle collector count overflows or underflows.",
"BuildRetry": false,
"ErrorPattern": "",
"ExcludeConsoleLog": false
}Failed tests:
- GC_API.GCHandleCollector_Usage_Usage._GCHandleCollector_Usage_Usage_sh()
- GC_Scenarios.DoublinkList_doublinkstay_doublinkstay._DoublinkList_doublinkstay_doublinkstay_sh()
- GC_Scenarios.DoublinkList_dlstack_dlstack._DoublinkList_dlstack_dlstack_sh()
GC/API/GCHandleCollector/Usage/Usage.sh [FAIL]
Unhandled Exception:
System.InvalidOperationException: Handle collector count overflows or underflows.
at System.Runtime.InteropServices.HandleCollector.Remove()
at HandleCollectorTest.Finalize()
[ERROR] FATAL UNHANDLED EXCEPTION: System.InvalidOperationException: Handle collector count overflows or underflows.
at System.Runtime.InteropServices.HandleCollector.Remove()
at HandleCollectorTest.Finalize()
Return code: 1
Raw output file: /root/helix/work/workitem/uploads/Reports/GC.API/GCHandleCollector/Usage/Usage.output.txt
Raw output:
BEGIN EXECUTION
/root/helix/work/correlation/corerun -p System.Reflection.Metadata.MetadataUpdater.IsSupported=false Usage.dll ''
Case 1 Passed!
100, 100
Case 2 Passed!
Expected: 100
Actual: 255
END EXECUTION - FAILED
Test Harness Exitcode is : 1
To run the test:
> set CORE_ROOT=/root/helix/work/correlation
> /root/helix/work/workitem/e/GC/API/GCHandleCollector/Usage/Usage.sh
Expected: True
Actual: False
Stack Trace:
at GC_API._GCHandleCollector_Usage_Usage_._GCHandleCollector_Usage_Usage_sh()
Output:
Unhandled Exception:
System.InvalidOperationException: Handle collector count overflows or underflows.
at System.Runtime.InteropServices.HandleCollector.Remove()
at HandleCollectorTest.Finalize()
[ERROR] FATAL UNHANDLED EXCEPTION: System.InvalidOperationException: Handle collector count overflows or underflows.
at System.Runtime.InteropServices.HandleCollector.Remove()
at HandleCollectorTest.Finalize()
Return code: 1
Raw output file: /root/helix/work/workitem/uploads/Reports/GC.API/GCHandleCollector/Usage/Usage.output.txt
Raw output:
BEGIN EXECUTION
/root/helix/work/correlation/corerun -p System.Reflection.Metadata.MetadataUpdater.IsSupported=false Usage.dll ''
Case 1 Passed!
100, 100
Case 2 Passed!
Expected: 100
Actual: 255
END EXECUTION - FAILED
Test Harness Exitcode is : 1
To run the test:
> set CORE_ROOT=/root/helix/work/correlation
> /root/helix/work/workitem/e/GC/API/GCHandleCollector/Usage/Usage.sh
Finished: GC.API.XUnitWrapper
Discovering: GC.LargeMemory.XUnitWrapper (method display = ClassAndMethod, method display options = None)
Discovered: GC.LargeMemory.XUnitWrapper (found 3 test cases)
Starting: GC.LargeMemory.XUnitWrapper (parallel test collections = on, max threads = 2)
Finished: GC.LargeMemory.XUnitWrapper
Discovering: GC.Scenarios.XUnitWrapper (method display = ClassAndMethod, method display options = None)
Discovered: GC.Scenarios.XUnitWrapper (found 31 test cases)
Starting: GC.Scenarios.XUnitWrapper (parallel test collections = on, max threads = 2)
GC/Scenarios/DoublinkList/doublinkstay/doublinkstay.sh [FAIL]
Return code: 1
Raw output file: /root/helix/work/workitem/uploads/Reports/GC.Scenarios/DoublinkList/doublinkstay/doublinkstay.output.txt
Raw output:
BEGIN EXECUTION
/root/helix/work/correlation/corerun -p System.Reflection.Metadata.MetadataUpdater.IsSupported=false doublinkstay.dll ''
Test should return with ExitCode 100 ...
19996 DLinkNodes finalized
Test Failed
Expected: 100
Actual: 1
END EXECUTION - FAILED
Test Harness Exitcode is : 1
To run the test:
> set CORE_ROOT=/root/helix/work/correlation
> /root/helix/work/workitem/e/GC/Scenarios/DoublinkList/doublinkstay/doublinkstay.sh
Expected: True
Actual: False
Stack Trace:
at GC_Scenarios._DoublinkList_doublinkstay_doublinkstay_._DoublinkList_doublinkstay_doublinkstay_sh()
Output:
Return code: 1
Raw output file: /root/helix/work/workitem/uploads/Reports/GC.Scenarios/DoublinkList/doublinkstay/doublinkstay.output.txt
Raw output:
BEGIN EXECUTION
/root/helix/work/correlation/corerun -p System.Reflection.Metadata.MetadataUpdater.IsSupported=false doublinkstay.dll ''
Test should return with ExitCode 100 ...
19996 DLinkNodes finalized
Test Failed
Expected: 100
Actual: 1
END EXECUTION - FAILED
Test Harness Exitcode is : 1
To run the test:
> set CORE_ROOT=/root/helix/work/correlation
> /root/helix/work/workitem/e/GC/Scenarios/DoublinkList/doublinkstay/doublinkstay.sh
GC/Scenarios/DoublinkList/dlstack/dlstack.sh [FAIL]
Return code: 1
Raw output file: /root/helix/work/workitem/uploads/Reports/GC.Scenarios/DoublinkList/dlstack/dlstack.output.txt
Raw output:
BEGIN EXECUTION
/root/helix/work/correlation/corerun -p System.Reflection.Metadata.MetadataUpdater.IsSupported=false dlstack.dll ''
Test should return with ExitCode 100 ...
Performing Collect/Wait/Collect cycle again
Finalized number stable at 9995
9995 DLinkNodes finalized
Test Failed
Expected: 100
Actual: 1
END EXECUTION - FAILED
Test Harness Exitcode is : 1
To run the test:
> set CORE_ROOT=/root/helix/work/correlation
> /root/helix/work/workitem/e/GC/Scenarios/DoublinkList/dlstack/dlstack.sh
Expected: True
Actual: False
Stack Trace:
at GC_Scenarios._DoublinkList_dlstack_dlstack_._DoublinkList_dlstack_dlstack_sh()
Output:
Return code: 1
Raw output file: /root/helix/work/workitem/uploads/Reports/GC.Scenarios/DoublinkList/dlstack/dlstack.output.txt
Raw output:
BEGIN EXECUTION
/root/helix/work/correlation/corerun -p System.Reflection.Metadata.MetadataUpdater.IsSupported=false dlstack.dll ''
Test should return with ExitCode 100 ...
Performing Collect/Wait/Collect cycle again
Finalized number stable at 9995
9995 DLinkNodes finalized
Test Failed
Expected: 100
Actual: 1
END EXECUTION - FAILED
Test Harness Exitcode is : 1
To run the test:
> set CORE_ROOT=/root/helix/work/correlation
> /root/helix/work/workitem/e/GC/Scenarios/DoublinkList/dlstack/dlstack.sh
Report
Summary
| 24-Hour Hit Count | 7-Day Hit Count | 1-Month Count |
|---|---|---|
| 0 | 0 | 0 |
Known issue validation
Build: 🔎 https://dev.azure.com/dnceng-public/public/_build/results?buildId=603897
Error message validated: [System.InvalidOperationException: Handle collector count overflows or underflows.]
Result validation: ✅ Known issue matched with the provided build.