Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Issues with assemblies of ABC transporters #216

Open
lafita opened this issue Apr 30, 2018 · 1 comment
Open

Issues with assemblies of ABC transporters #216

lafita opened this issue Apr 30, 2018 · 1 comment
Labels
Milestone

Comments

@lafita
Copy link
Member

lafita commented Apr 30, 2018

The assemblies of ABC transporter 4FI3 http://eppic-web.org/ewui/#id/4fi3 seem to be wrong, since assemblies 6,7 and 8 are actually the same one but have different engaged interfaces (7 and 8 should have merged into 6).

Also the structure of the assembly seems wrong, since chain F is positioned completely wrong on the side and clashing with other chains. There must be a translation problem that causes that.

http://eppic-web.org/ewui/ewui/jmolViewer?id=4fi3&type=assembly&input=4fi3&assemblyId=6&coordsFormat=cif&size=644

The same happens with another ABC transporter 2QI9.

@lafita lafita added the bug label Apr 30, 2018
@lafita lafita added this to the 3.1 milestone Apr 30, 2018
@josemduarte
Copy link
Contributor

The second issue (clash in structure of the assembly) might have been fixed with upgrade to biojava 5. Needs testing though.

@josemduarte josemduarte modified the milestones: 3.1, 3.0.6 May 1, 2018