Solis battery control broken #25158

@bertgoos

Description

@bertgoos

Describe the bug

Version: v0.209.7
Inverter: Solis S6-EH3P10K-H-ZP

Fuctionality regarding the battery behavior seems broken. It's not possible to block the battery during charging so all the power is provided by the grid / pv instead of the battery.

Also charging the battery via the grid is not possible at the moment.

Steps to reproduce

set price to charge battery from the grid / charge car with function 'block battery' function in PV modus enabled.

Configuration details

Version: v0.209.7
Inverter: Solis S6-EH3P10K-H-ZP

Log details

[httpd ] TRACE 2025/11/08 14:48:56 DELETE /api/batterygridchargelimit
[site ] DEBUG 2025/11/08 14:48:56 set grid charge limit: <nil>
[site ] DEBUG 2025/11/08 14:48:56 ----
[lp-1 ] DEBUG 2025/11/08 14:48:56 charge power: 0W
[lp-1 ] DEBUG 2025/11/08 14:48:56 charge currents: [0.009 0.015 0.008]A
[homewizard] TRACE 2025/11/08 14:48:56 GET http://192.168.0.58/api/v1/data
[db:7 ] TRACE 2025/11/08 14:48:56 modbus: send 03 a2 00 00 00 06 01 04 81 7d 00 02
[homewizard] TRACE 2025/11/08 14:48:56 {"wifi_ssid":"Sharon en Bert IOT","wifi_strength":70,"smr_version":50,"meter_model":"LGF5E360","unique_id":"314C475A30353735393133323236","active_tariff":2,"total_power_import_kwh":1096.118,"total_power_import_t1_kwh":312.330,"total_power_import_t2_kwh":783.788,"total_power_export_kwh":3282.096,"total_power_export_t1_kwh":2467.199,"total_power_export_t2_kwh":814.897,"active_power_w":-11.000,"active_power_l1_w":-47.000,"active_power_l2_w":-22.000,"active_power_l3_w":57.000,"active_voltage_l1_v":231.600,"active_voltage_l2_v":233.600,"active_voltage_l3_v":232.900,"active_current_a":2.000,"active_current_l1_a":1.300,"active_current_l2_a":0.350,"active_current_l3_a":0.350,"active_power_average_w":3.000,"montly_power_peak_w":5868.000,"montly_power_peak_timestamp":251107013000,"external":[]}
[site ] DEBUG 2025/11/08 14:48:56 grid power: -11W
[site ] DEBUG 2025/11/08 14:48:56 grid currents: [1.3 0.35 0.35]A
[db:7 ] TRACE 2025/11/08 14:48:57 modbus: recv 03 a2 00 00 00 07 01 04 04 00 00 00 67
[db:7 ] TRACE 2025/11/08 14:48:57 modbus: send 03 a3 00 00 00 06 01 04 81 6f 00 01
[db:7 ] TRACE 2025/11/08 14:48:58 modbus: recv 03 a3 00 00 00 05 01 04 02 00 01
[site ] DEBUG 2025/11/08 14:48:58 battery 1 power: 103W
[db:7 ] TRACE 2025/11/08 14:48:58 modbus: send 03 a4 00 00 00 06 01 04 81 8d 00 02
[db:7 ] TRACE 2025/11/08 14:48:59 modbus: recv 03 a4 00 00 00 07 01 04 04 00 00 02 77
[db:7 ] TRACE 2025/11/08 14:48:59 modbus: send 03 a5 00 00 00 06 01 04 81 73 00 01
[db:7 ] TRACE 2025/11/08 14:48:59 modbus: recv 03 a5 00 00 00 05 01 04 02 00 1e
[site ] DEBUG 2025/11/08 14:48:59 battery 1 soc: 30%
[site ] DEBUG 2025/11/08 14:48:59 pv power: 11W
[site ] DEBUG 2025/11/08 14:48:59 site power: 92W
[lp-1 ] DEBUG 2025/11/08 14:48:59 charge total import: 1151.513kWh
[lp-1 ] DEBUG 2025/11/08 14:48:59 charger status: B
[site ] DEBUG 2025/11/08 14:48:59 solar forecast: accumulated 0.002Wh from 2025-11-08 14:48:51 +0100 CET to 2025-11-08 14:48:59 +0100 CET
[site ] DEBUG 2025/11/08 14:48:59 solar forecast: produced 0.000
[site ] DEBUG 2025/11/08 14:48:59 solar forecast: accumulated 0.744kWh, produced 0.000kWh, scale 0.000
[db:7 ] TRACE 2025/11/08 14:48:59 modbus: send 03 a6 00 00 00 06 01 06 a8 10 00 14
[httpd ] TRACE 2025/11/08 14:49:00 GET /api/auth/status
[httpd ] TRACE 2025/11/08 14:49:00 GET /api/system/log
[httpd ] TRACE 2025/11/08 14:49:00 GET /api/system/log/areas
[db:7 ] TRACE 2025/11/08 14:49:00 modbus: recv 03 a6 00 00 00 06 01 06 a8 10 00 14
[site ] DEBUG 2025/11/08 14:49:00 set battery mode: normal
[proxy-5021] TRACE 2025/11/08 14:49:03 read input: id 1 addr 33041 qty 3
[proxy-5021] TRACE 2025/11/08 14:49:03 read input: 01 f4 00 00 00 00
[proxy-5021] TRACE 2025/11/08 14:49:03 read input: id 1 addr 33049 qty 10
[httpd ] TRACE 2025/11/08 14:49:04 GET /api/system/log
[proxy-5021] TRACE 2025/11/08 14:49:04 read input: 0c 96 00 03 09 b7 00 03 00 13 00 00 00 31 00 00 00 00 00 ab
[proxy-5021] TRACE 2025/11/08 14:49:04 read input: id 1 addr 33070 qty 15
[proxy-5021] TRACE 2025/11/08 14:49:05 read input: 00 00 19 7a 0c d7 09 13 09 0c 09 18 00 03 00 04 00 03 00 00 01 0e ff ff ff f6 00 00 01 0e
[proxy-5021] TRACE 2025/11/08 14:49:05 read input: id 1 addr 33093 qty 4
[proxy-5021] TRACE 2025/11/08 14:49:06 read input: 00 f5 13 8a 00 03 00 00
[proxy-5021] TRACE 2025/11/08 14:49:06 read input: id 1 addr 33122 qty 1
[proxy-5021] TRACE 2025/11/08 14:49:06 read input: 00 02
[proxy-5021] TRACE 2025/11/08 14:49:06 read input: id 1 addr 33132 qty 25
[site ] DEBUG 2025/11/08 14:49:06 ----
[lp-1 ] DEBUG 2025/11/08 14:49:06 charge power: 0W
[lp-1 ] DEBUG 2025/11/08 14:49:06 charge currents: [0.009 0.015 0.008]A
[homewizard] TRACE 2025/11/08 14:49:06 GET http://192.168.0.58/api/v1/data
[homewizard] TRACE 2025/11/08 14:49:06 {"wifi_ssid":"Sharon en Bert IOT","wifi_strength":70,"smr_version":50,"meter_model":"LGF5E360","unique_id":"314C475A30353735393133323236","active_tariff":2,"total_power_import_kwh":1096.119,"total_power_import_t1_kwh":312.330,"total_power_import_t2_kwh":783.789,"total_power_export_kwh":3282.096,"total_power_export_t1_kwh":2467.199,"total_power_export_t2_kwh":814.897,"active_power_w":-9.000,"active_power_l1_w":-47.000,"active_power_l2_w":-20.000,"active_power_l3_w":58.000,"active_voltage_l1_v":231.700,"active_voltage_l2_v":233.400,"active_voltage_l3_v":233.100,"active_current_a":2.010,"active_current_l1_a":1.310,"active_current_l2_a":0.340,"active_current_l3_a":0.360,"active_power_average_w":3.000,"montly_power_peak_w":5868.000,"montly_power_peak_timestamp":251107013000,"external":[]}
[site ] DEBUG 2025/11/08 14:49:06 grid power: -9W
[site ] DEBUG 2025/11/08 14:49:06 grid currents: [1.31 0.34 0.36]A
[proxy-5021] TRACE 2025/11/08 14:49:07 read input: 00 21 14 42 00 03 00 01 14 42 09 23 00 00 00 1e 00 64 ca b2 ff fd 03 20 03 20 00 00 00 00 00 e6 00 00 00 00 00 9b 00 00 00 fa 09 0c 00 00 09 19 00 00
[db:7 ] TRACE 2025/11/08 14:49:07 modbus: send 03 ad 00 00 00 06 01 04 81 7d 00 02
[proxy-5021] TRACE 2025/11/08 14:49:07 read input: id 1 addr 34328 qty 6
[db:7 ] TRACE 2025/11/08 14:49:08 modbus: recv 03 ad 00 00 00 07 01 04 04 00 00 00 9b
[db:7 ] TRACE 2025/11/08 14:49:08 modbus: send 03 ae 00 00 00 06 01 04 81 6f 00 01
[db:7 ] TRACE 2025/11/08 14:49:08 modbus: recv 03 ae 00 00 00 05 01 04 02 00 01
[site ] DEBUG 2025/11/08 14:49:08 battery 1 power: 155W
[proxy-5021] TRACE 2025/11/08 14:49:09 read input: 00 00 00 00 00 00 00 00 00 00 00 00
[db:7 ] TRACE 2025/11/08 14:49:09 modbus: send 03 b0 00 00 00 06 01 04 81 8d 00 02
[proxy-5021] TRACE 2025/11/08 14:49:09 read input: id 1 addr 33251 qty 36
[httpd ] TRACE 2025/11/08 14:49:10 GET /api/system/log

What type of operating system or environment does evcc run on?

HomeAssistant Add-on

External automation

  • I have made sure that no external automation like HomeAssistant or Node-RED is active or accessing any of the mentioned devices when this issue occurs.

Nightly build

  • I have verified that the issue is reproducible with the latest nightly build

Version

No response

Metadata

Metadata

Assignees

No one assigned

    Labels

    devicesSpecific device support

    Type

    No type

    Projects

    No projects

    Milestone

    No milestone

    Relationships

    None yet

    Development

    No branches or pull requests

    Issue actions