Example Modbus RTU Server
This example shows how to configure a Modbus RTU server.
Written by FACTS Engineering
Copyright (c) 2023 FACTS Engineering, LLC
Licensed under the MIT license.
"""
import board
import digitalio
from uModBus.serial import RTUServer
import p1am_200_helpers as helpers # For P1AM-SERIAL
from rs485_wrapper import RS485 # If using an RS485 transceiver
led = digitalio.DigitalInOut(board.LED)
led.switch_to_output()
switch = digitalio.DigitalInOut(board.SWITCH)
# For P1AM-SERIAL using RS232
comm = helpers.get_serial(1, mode=232, baudrate=115200)
# For P1AM-SERIAL using RS485
# uart, de = helpers.get_serial(1, mode=485, baudrate=115200) # For P1AM-SERIAL
# comm = RS485(uart, de, auto_idle_time=.05) # If using an RS485 transceiver
# For generic RS232
# comm = busio.UART(board.TX1, board.RX1, baudrate=115200)
mb_server = RTUServer(
comm,
unit_addr=1,
number_coils=32,
number_input_registers=255,
number_discrete_inputs=16,
number_holding_registers=10,
)
mb_server.input_registers = list(range(255)) # set input register value to their address
mb_server.discrete_inputs[5] = True # set input register 5 to True
count = 0
while True:
mb_server.poll(timeout=.5) # Regularly poll the modbus server to handle incoming requests
mb_server.discrete_inputs[0] = switch.value # set discrete input 0 to switch value
mb_server.holding_registers[0] = count # set holding register 0 to count value
led.value = mb_server.coils[0] # set led to output value
count += 1
if count > 32767:
count = 0 # reset count