@@ -7,13 +7,22 @@ In order to provision and manage the switches that comprise the fabric, an out o
77
## Control Node
88

99
- Fast SSDs for system/root is mandatory for Control Nodes
10-
- NVMe SSDs are recommended
11-
- DRAM-less NAND SSDs are not supported (e.g. Crucial BX500)
10+
- NVMe SSDs are recommended
11+
- DRAM-less NAND SSDs are not supported (e.g. Crucial BX500)
1212
- 10 GbE port for connection to management network is recommended
1313
- Minimal (non-HA) setup is a single Control Node
1414
- (Future) Full (HA) setup is at least 3 Control Nodes
1515
- (Future) Extra nodes could be used for things like Logging, Monitoring, Alerting stack, and more
1616

17+
In internal testing Hedgehog uses a server with the following specifications:
18+
19+
- CPU - AMD EPYC 4344P
20+
- Memory - 32 GiB DDR5 ECC 4800MT/s
21+
- Storage - PCIe Gen 4 NVMe M.2 400GB
22+
- Network - AOC-STG-i4S Intel X710-BM1 controller
23+
- Motherboard - H13SAE-MF
24+
25+
1726
### Non-HA (minimal) setup - 1 Control Node
1827

1928
- Control Node runs non-HA Kubernetes Control Plane installation with non-HA Hedgehog Fabric Control Plane on top of it

0 commit comments