Description
The documentation has added values for contact resistances taken from my spreadsheet. However, upon reviewing some of the SkyWater etest data, I realize that I had written down the value for the LICON-to-poly contact resistance under the MCON contact.
The document page needing correcting is here: https://skywater-pdk.readthedocs.io/en/main/rules/rcx.html#resistance-rules
Existing Documentation
LICON contact | 15000
MCON contact | 152000
Correct Documentation
LICON contact to poly | 152000
LICON contact to ndiff | 185000
LICON contact to pdiff | 585000
MCON contact | 9300
Note that there are significant differences in the LICON resistance depending on what material it contacts, so there should be three separate entries for this contact resistance.