Skip to content

Latest commit

 

History

History
69 lines (55 loc) · 5.5 KB

README.md

File metadata and controls

69 lines (55 loc) · 5.5 KB

COMPEST

DOI

An interface connecting COMSOL Multiphysics and PEST to solve inverse modelling problems using forward finite element models.

COMPEST is an interface between PEST and COMSOL Multiphysics

The paper

Halloran et al. (2019), https://doi.org/10.1016/j.cageo.2019.02.001 (see details below or folder extras/).

Author and contact

Written by Dr. Landon J.S. Halloran, 2018. www.ljsh.ca

Overview

COMPEST is a program written in java that enables advanced parameter estimation, sensitivity analysis, uncertainty analysis, and data-worth analysis to investigate and solve inverse problems using forward finite-element models. The software functions as a link between PEST and COMSOL Multiphysics. Although the software's functionality has been demonstrated with application to isotopic fractionation in the diffusion and degradation of chlorinated contaminants in the subsurface, any problem that can be modelled in COMSOL Multiphysics can be handled with some modification of the code.

Requirements

  • (proprietary) COMSOL Multiphysics Server (tested with ver. 5.3) and COMSOL Java API
  • (free) Java IDE (tested with ver. 1.8),
  • (free) PEST (ver. 12.1.0 executable included here)

How-to:

  • Firstly, it is recommended you read the article: (Halloran et al., 2019).
  • Secondly, it is recommended to have some basic familiarity with PEST (see Doherty, 2016).
  1. Define:
    1. Define problem for which observations (measurements) exist and for which a finite-element model can be created.
    2. Choose which parameters to vary (e.g., to be estimated, to investigate uncertainty, etc.)
  2. Prepare COMSOL Model:
    1. Set up time-dependent model in COMSOL. (Note: stationary models may work too, but this will require some creativity on your part).
    2. Ensure all parameters to be varied are defined as global "variables" (i.e. not "parameters").
    3. Set model output times to the times of the observations.
    4. In Results>Data Sets set the observation points using Cut Point 1D or similar. Set the Point Number Variable to cpt1 (alternatively COMPEST.java will need to be modified and recompiled).
    5. Delete the values of parameters to be varied (having them present can result in a duplicate definition error).
    6. Launch the COMSOL Server in a separate command prompt using "C:\XXXXXX\COMSOL53\Multiphysics\bin\win64\comsolmphserver.exe" -multi on where XXXXXX is the location of your COMSOL installation.
  3. Prepare PEST:
    1. Prepare .tpl file. This file tells PEST how to write parameter values to a .inp file during execution - this .inp file is read by COMPEST.
    2. Prepare your observations/measurements and their corresponding outputs from the model.
    3. Prepare .ins file(s), one file for each modelled observation output type. These files tell PEST how to read model output data in .dat (or other) files written by COMPEST.
    4. Prepare .bat file with line to execute COMPEST (see Useful Commands below).
    5. Prepare .pst (PEST control file) file. There are utility programs (see Doherty 2016) that are are useful for this.
  4. Prepare COMPEST:
    1. If needed (e.g., COMSOL Java API plugins not in same location as mentioned in Useful Commands below), compile the java class file using javac -cp "C:\XXXXXX\COMSOL53\Multiphysics\plugins\*" COMPEST.java where XXXXXX is the location of your COMSOL installation.
    2. Define all parametes in the define.properties file (an explanation of all parameters is contained in the file header).
    3. Ensure batch file is referring to correct location of COMSOL Java API files (see Useful Commands below).
  5. Final prep and checks:
    1. (optional) Run utility program PESTCHEK to check if .pst file has been set up properly.
    2. (optional) Run the .pst file once to calculate the Jacobian with the initial values. Then run the utility program PWTADJ1 to adjust the weights of each obervation group.
  6. Make it happen:
    1. Execute the PEST-COMPEST-COMSOL by typing PEST PCFFILENAME in the command prompt, where PCFFILENAME is the name of the .pst "PEST Control File".

Examples

Four examples are presented in their own stand-alone folders. The first three are discussed in the main article (Halloran et al., see "References" below) and the fourth is presented in the article's Supplementary Information document.

Useful commands (in Windows cmd):

To compile COMPEST (run in the project directory):
javac -cp "C:\Program Files\COMSOL\COMSOL53\Multiphysics\plugins\*" -verbose COMPEST.java

To execute COMPEST:
java -cp .;"C:\Program Files\COMSOL\COMSOL53\Multiphysics\plugins\*" COMPEST

To launch COMSOL server so that it doesn't close upon disconnect:
"C:\Program Files\COMSOL\COMSOL53\Multiphysics\bin\win64\comsolmphserver.exe" -multi on

Replace the paths with the locations of your COMSOL java API files or server executable where necessary.

References:

  • Doherty, J. (2016). PEST Model-Independent Parameter Estimation User Manual Part I: PEST, SENSAN and Global Optimisers (6th ed.). Brisbane: Watermark Numerical Computing.
  • Halloran, L.J.S., P. Brunner, & D. Hunkeler (2019). "COMPEST, a PEST-COMSOL interface for inverse multiphysics modelling: Development and application to isotopic fractionation of groundwater contaminants," Computers and Geosciences. https://doi.org/10.1016/j.cageo.2019.02.001