Open
Description
I have realized that the reason for some erronous readings from some sensors, is due to the fact that the sensor-init is never done.
MC[I]: Booting ESP8266 device...
MC[I]: WIFI not connected, trying connection...
MC[I]: Connecting to WiFi with ssid[1421530] and with password............OK
MC[I]: WiFi BSSID:[00:02:61:A8:32:58], RSSI:[-68 dBm, 64 %], IP:[192.168.1.148], StatusCode:[3]
MC[I]: Configuration(NodeEUI:[ESP_2D5A26], Mqtt{mDNS-status:[0], Server:[192.168.1.197], Port:[1883], FeedId:[esp], User:[]})
MC[I]: MQTT settings(Broker:[192.168.1.197], Port:[1883])
MC[I]: MQTT authenticating as anonymous
MC[I]: MQTT connection failed, rc=-4
MC[I]: Initialization done...
MC[I]: MQTT failed! Retryting to connect...
MC[I]: MQTT settings(Broker:[192.168.1.197], Port:[1883])
MC[I]: MQTT authenticating as anonymous
MC[I]: MQTT connected :)
MC[I]: MQTT topic subscribed:[in_esp/ESP_2D5A26/#]
Envoie de Luxmeter:81
Temp2: 93
Requesting temperatures...DONE
Device Address: 0000000000000000 Temp C: -127.00 Temp F: -196.60
Device Address: 0000000000000000 Temp C: -127.00 Temp F: -196.60
Envoie de Luxmeter:81
Temp2: 93
It seems that the device starts probing sensors without the before() or setup() is called. In the above, these two functions are declared:
void setup() {
MC_SERIAL.print("Core: Setup running... ");
}
and
void before() {
MC_SERIAL.print("Core: Before running... ");
[init code goes here]
}
Metadata