HomeAssistant Status Module

Introduction

The HomeAssistant Status Module provides a mechanism to publish sensor states to HomeAssistant via the HomeAssistant API.

The module uses a long-term access key that is created through the HASS web interface, which allows the module to send updates to the sensors listed below without needing hard-coded credentials.

HomeAssistant Sensors

The following sensors and their values are published to HomeAsssitant via the HomeAssistant HTTP API.

HomeAssistant Sensor Value Example
sensor.twcmanager_all_total_amps_in_use Float: Amps in use across all slaves 16.24
sensor.twcmanager_charger_amps_in_use Float: Amps in use for given Slave TWC 8.52
sensor.twcmanager_charger_amps_max Integer: Reported maximum amperage per Slave TWC 32
sensor.twcmanager_charger_cars_charging Boolean: Will be 0 if Slave TWC does not have a connected charging vehicle, or 1 if it does.
sensor.twcmanager_charger_charger_load_w Integer: Actual power being consumed as reported by the Slave TWC. 2977
sensor.twcmanager_charger_current_vehicle_vin String: The VIN of a vehicle currently charging from this Slave TWC.
sensor.twcmanager_charger_last_vehicle_vin String: The VIN of the vehicle previously charging from this Slave TWC.
sensor.twcmanager_charger_lifetime_kwh Integer: Lifetime kWh output by specified charger. 159
sensor.twcmanager_charger_power Float: Actual amps being consumed as reported by the Slave TWC. 14.51
sensor.twcmanager_charger_state Integer: State code reported by TWC. Please see table below for state codes.
sensor.twcmanager_charger_voltage_phase_phase Integer: Volts per phase (a/b/c) per Slave TWC 243
sensor.twcmanager_config_min_amps_per_twc Integer: Minimum amps to charge per TWC (from config) 6
sensor.twcmanager_config_max_amps_for_slaves Integer: Total number of amps on power circuit to divide amongst Slave TWCs 32

State Codes

The following state codes are reported by Slave TWCs:

State Code Description
0 Ready. Car may or may not be plugged in to TWC
1 Plugged in and charging
2 Error
3 Plugged in, do not charge (vehicle finished charging or error)
4 Plugged in, ready to charge or charge is scheduled
5 Busy
6 TBA. Version 2 only.
7 TBA. Version 2 only.
8 Starting to charge.
9 TBA. Version 2 only.
10 Amp adjustment period complete.
15 Unknown.