Build and installation of psi46expert for the digital testboard

  1. Dependencies

To install psi46expert for the digital testboard a few libraries and programs are required:

  • libusb-1.0 and libusb-0.1 normally available as a package for your Linux distribution

  • libftd2xx-1.1.x can be downloaded from http://www.ftdichip.com/Drivers/D2XX.htm Follow the instructions given on the website

  • ROOT download from http://root.cern.ch or try your Linux distriution's package repository export LD_LIBRARY_PATH=$HOME/root/lib:$LD_LIBRARY_PATH

    cd $HOME/root/lib ln -s /usr/lib/libusb.so libusb.so

  • libtool, autoconf, automake always available as a package for your Linux distribution, normally installed by default

If these are installed in special directories (not /usr or /usr/local) then you have to take measures that the compiler finds your files (set and export PATH, CPATH, LIBRARY_PATH environment variables).

  1. Preparing the sources after SVN (subversion) checkout

After checking out the sources from SVN, run the following command in the working directory:

./autogen.sh
  1. Compiling the sources

Run ./configure [--prefix=SOMEDIR] make or to use the ftd2xx libraries: ./configure [--prefix=SOMEDIR] --with-ftd2xx make

with the option [--prefix=SOMEDIR] optional. The prefix determines where the installed files would go. By default this is /usr/local (binaries would go to /usr/local/bin, libraries to /usr/local/lib and so on).

Multiple versions (e.g. branches) of the software can be installed in parallel by changing the names of the produced programs by running

./configure [--prefix=SOMEDIR] --program-suffix=SUFFIX

Program names will then be for example psi46expertSUFFIX. Beware that library names will not be affected by this (see below).

NOTE: Some linux versions, like RedHat Enterprise 6, have an old glibc version not compatible with libftd2xx-1.1.x

To use the software on such a linux system you can install GLIBC2.14 manually and use the following commands for compiling

export LD_PRELOAD="/PATH/TO/GLIBC2.14/lib/libc.so.6:${LD_PRELOAD}"
./configure LDFLAGS="-L/PATH/TO/GLIBC2.14/lib"
  1. Installing the software

The software is installed by typing

make install

If multiple versions of the software should be installed in parallel (see above) then the installation will overwrite previously installed library versions (like libpsi46ana for example). You can avoid this by specifying

./configure <other args> --libdir=$PWD

which doesn't really install the libraries at all.

  1. Running the software

You will need a configuration directory for Modules/ROCs:

cp -r data/defaultParameters<X> WHEREVER

Then you can run

psi46expert -dir WHEREVER
  1. Frequent problems

  1. If you have an old test board, you need to make sure that the usb class can find it by using the method usb.SetProductID(0x6001) in the code (where 0x6001 corresponds to the product ID of the old FT chips that the previous boards were equipped with)

  2. If ./autogen.sh does not work, you probably don't have libtool installed. Or autoconf, automake. These are standard packages in a Linux system. Check your Linux manual on how to install packages.

  3. If ./configure doesn't find some header or library, install what is requested and make sure it can be found by the compiler. The libraries libusb-1.0.so or libusb-0.1.so may require a symbolic link to libusb.so. This may also be true for libftd2xx. Make sure you follow the instructions of the libftd2xx library! libusb comes as a package in all Linux distributions. There are two versions: 0.1 and 1.0. Install both to be safe. (Your favourite distribution should provide the packages.) For libraries in special directories you can use

    export PATH=$PATH:whatever export CPATH=$CPATH:whatever export LIBRARY_PATH=$LIBRARY_PATH:whatever

before calling ./configure . This is best put in your .bashrc
file in your home directory.
  1. If 'make' fails, you should talk to a code maintainer. There are two cases which is known to fail: On is that the call to rootcint fails because it cannot find the libraries. Make sure that you set LD_LIBRARY_PATH correctly:

    export LD_LIBRARY_PATH=$LD_LIBRARY_PATH:YOURPATH

The other case is if you try to compile
the software against the older version libftd2xx-0.4.x
on a 32 bit machine, then there may be a compilation error
in USBInterface.cc, depending on which compiler version you
are using. It might say something about being unable to
convert a 'unsigned long *' into a 'unsigned int *'. On a
32 bit Linux system, they are actually exactly the same, so
you can pass the variable

	./configure CFLAGS=-fpermissive

to the configuration script, which should make the compiler
ignore the problem.
  1. If psi46expert won't start because a library is missing, set your custom library path with

    export LD_LIBRARY_PATH=$LD_LIBRARY_PATH:YOURPATH

  2. If psi46expert cannot open a port to the testboard, then make sure the testboard name is correct in the configParameters.dat file in you config directory. If this is the case, make sure that you have write access to your USB devices:

    ls -l /dev/bus/usb/00?/*

You can change these permissions permanently if you create a file
/etc/udev/rules.d/10-testboard.rules which contains

	SUBSYSTEM == "usb", ATTR{product} == "DLP-USB245M", GROUP="usb", MODE="0664"

and create a group "usb" and add yourself to that group. Newly
plugged devices will have the correct permissions. For the
libftd2xx-0.4.x library version it may be that you need the
usbfs. You can get this by putting the following line into your
/etc/fstab file:

	none /proc/bus/usb usbfs devgid=1000,devmode=0660 0 0

where you should replace the number 1000 with the group id of
your group 'usb'. You can then either reboot the machine or
do a

	mount -a

as root.
Lastly, it is possible that the automatic detachment of the
usb serial kernel modules was not enabled during compilation.
This happens if the libusb-1.0 headers are missing on the
system. Some systems have -devel packages for their libraries
and you should install such package and then recompile and
reinstall psi46expert.
  1. If you wish to use other devices with FTDI chips that require the bit bang mode and/or the kernel modules usbserial and ftdi_sio, then you should install libftd2xx-1.1.x.

  2. Some linux versions, like RedHat Enterprise 6, have an old glibc version not compatible with libftd2xx-1.1.x

    To use the software on such a linux system you can install GLIBC2.14 manually and use the following commands for compiling

    export LD_PRELOAD="/PATH/TO/GLIBC2.14/lib/libc.so.6:${LD_PRELOAD}" ./configure LDFLAGS="-L/PATH/TO/GLIBC2.14/lib"

  3. If all things fail, you should talk to a code maintainer. Post a message to the hypernews list 'Pixel psi46 Testboard':

    [email protected]

This requires a CERN account.