You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
SerialConsole was deprecated in Manager v1_10_0 and has been
removed in bmcweb [1].
Because the SerialConsole values were not available anymore, the
Managers were not displayed because "setBmcInfo" couldn't find the
"SerialConsole" properties. THe following error will be logged:
```
TypeError: Cannot read properties of undefined (reading 'ConnectTypesSupported')
at Wa.setBmcInfo (app.25e72670.js:58:745295)
at app.25e72670.js:50:2774
at app.25e72670.js:50:10113
at Array.forEach (<anonymous>)
at app.25e72670.js:50:10092
at Wa._withCommit (app.25e72670.js:50:11953)
at Wa.commit (app.25e72670.js:50:10066)
at Wa.commit (app.25e72670.js:50:9518)
at o.commit (app.25e72670.js:50:2216)
at app.25e72670.js:58:745747
```
[1]: openbmc/bmcweb@fa800c8
Tested: BMC manager being listed in the inventory and serial console
variables being displayed for the system.
Change-Id: I1a24178717805ca50eef2c89042c0bd9ede1d5bc
Signed-off-by: Tan Siewert <[email protected]>
0 commit comments