I believe there is an issue in src/codec/rtu/mod.rs in fn request_pdu_len.
You may want to check the Modbus application protocol spec, sections 6.11 and 6.12, to make sure.
IMHO, the function should look like this:
pub const fn request_pdu_len(adu_buf: &[u8]) -> Result<Option<usize>> {
if adu_buf.len() < 2 {
return Ok(None);
}
let fn_code = adu_buf[1];
let len = match fn_code {
0x01..=0x06 => Some(5),
0x07 | 0x0B | 0x0C | 0x11 => Some(1),
0x0F => {
if adu_buf.len() > 6
&& u16::from_be_bytes([adu_buf[4], adu_buf[5]]) == adu_buf[6] as u16
{
Some(6 + (adu_buf[6] as usize))
} else {
// incomplete frame
None
}
}
0x10 => {
if adu_buf.len() > 6
&& u16::from_be_bytes([adu_buf[4], adu_buf[5]]).saturating_mul(2)
== adu_buf[6] as u16
{
Some(6 + (adu_buf[6] as usize))
} else {
// incomplete frame
None
}
}
0x16 => Some(7),
0x18 => Some(3),
0x17 => {
if adu_buf.len() > 10 {
Some(10 + adu_buf[10] as usize)
} else {
// incomplete frame
None
}
}
_ => {
return Err(Error::FnCode(fn_code));
}
};
Ok(len)
}
Specifically, for function codes 0x0F and 0x10, adu_buf[6], not adu_buf[4], should be used to determine the PDU length.
This change fixed an issue in my application. I'd appreciate it if you integrate it in your crate.