attachment_project_id |
the Interconnect project ID. |
string |
n/a |
yes |
cloud_router_labels |
A map of suffixes for labelling vlans with four entries like "vlan_1" => "suffix1" with keys from vlan_1 to vlan_4 . |
map(string) |
{} |
no |
preactivate |
Preactivate Partner Interconnect attachments, works only for level3 Partner Interconnect |
string |
false |
no |
region1 |
First subnet region. The Partner Interconnect module only configures two regions. |
string |
n/a |
yes |
region1_interconnect1_location |
Name of the interconnect location used in the creation of the Interconnect for the first location of region1 |
string |
n/a |
yes |
region1_interconnect1_onprem_dc |
Name of the on premisses data center used in the creation of the Interconnect for the first location of region1. |
string |
n/a |
yes |
region1_interconnect2_location |
Name of the interconnect location used in the creation of the Interconnect for the second location of region1 |
string |
n/a |
yes |
region1_interconnect2_onprem_dc |
Name of the on premisses data center used in the creation of the Interconnect for the second location of region1. |
string |
n/a |
yes |
region1_router1_name |
Name of the Router 1 for Region 1 where the attachment resides. |
string |
n/a |
yes |
region1_router2_name |
Name of the Router 2 for Region 1 where the attachment resides. |
string |
n/a |
yes |
region2 |
Second subnet region. The Partner Interconnect module only configures two regions. |
string |
n/a |
yes |
region2_interconnect1_location |
Name of the interconnect location used in the creation of the Interconnect for the first location of region2 |
string |
n/a |
yes |
region2_interconnect1_onprem_dc |
Name of the on premisses data center used in the creation of the Interconnect for the first location of region2. |
string |
n/a |
yes |
region2_interconnect2_location |
Name of the interconnect location used in the creation of the Interconnect for the second location of region2 |
string |
n/a |
yes |
region2_interconnect2_onprem_dc |
Name of the on premisses data center used in the creation of the Interconnect for the second location of region2. |
string |
n/a |
yes |
region2_router1_name |
Name of the Router 1 for Region 2 where the attachment resides. |
string |
n/a |
yes |
region2_router2_name |
Name of the Router 2 for Region 2 where the attachment resides |
string |
n/a |
yes |
vpc_name |
Label to identify the VPC associated with shared VPC that will use the Interconnect. |
string |
n/a |
yes |