@sztanpet

When trying to run cron jobs with go-crond from a container, and a new deployment happens, the container receives a SIGTERM to signal the request for termination. This causes go-crond to exit immediately, while all running jobs never receive a signal. The exit of go-crond signals openshift that the container shut down, terminating the container and all still-running jobs un-cleanly.

My expectation is: when go-crond receives SIGTERM it should send all running jobs the same SIGTERM and wait for them to exit, only then should go-crond exit. This would let the jobs exit cleanly.