fix qmd.x error when print(molecular dipolemoment) is enabled with static sampling properties #4
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
For an MD simulation, when I enabled the print for molecular dipole moment (the last 1 in the print option), along with static sampling steps (ng), it resulted in a qmd.x crash.
On further debugging the source code, I observed that in the function "md_static_prepare_traj" at line 110, the string "file_position" is again passed in quotes "". This was resulting in a qmd.x crash with the following error message: "Bad POSITION parameter in"
I have made a small fix for this typo error and found the qmd.x working for the given scenario.
Input_water_acmd.txt