Notifications
You must be signed in to change notification settings - Fork 13
Creating and Editing Protocols ‐ JSON ‐ CSV
"Protocols" are defined through 2 file types.
The first is .json, which contains the default settings and optionally codes.
The .csv files hold the registry or address definitions.
CSV = comma seperated values... spreadsheets. delimeter for csv can be , or ; ( not both )
variable name | data type | register | documented name | description | writable | values |
---|
provides a user-friendly name to work with, while retaining the original documented name; since a lot of variable names are up to interpretation.
Original variable name provided from protocol documention; when variable name is not specified, this name is used.
Defines the expected data type for the register / map entry
Type | Description |
---|---|
USHORT | A two byte ( 16 bit ) positive number. For protocols that return 2 byte values, this is the default type. |
BYTE | A single byte ( 8 bit ) positive number. |
UINT | A four byte ( 32 bit ) positive number. |
INT | A four byte ( 32 bit ) signed number (positive or negative) |
16BIT_FLAGS | two bytes split into 16 bits, each bit represents on/off flag which is defined as b#. this will translate into 16x 0/1s if no "codes" are defined. |
8BIT_FLAGS | A single byte split into 8 bit flags. see 16BIT_FLAGS |
32BIT_FLAGS | four bytes split into 32 bit flags. see 16BIT_FLAGS |
#bit | A unsigned number comprised of # of bits. for example, 3bit is a 3 bit positive number (0 to 7). |
ASCII | ascii text representation of data. |
ASCII.# | for protocols with an undefined "registry" size, the length can be specified. ie: ASCII.7 will return a 7 character long string. |
Register defines the location or for other protocols the main command / id. The registers are defined in decimal form. a prefix of "x" is acceptable for hexadecimal.
For ASCII or other MultiRegister Data Types, register ranges can be defined:
7~14
a prefix of "r" will specify that the registers be "read" in backwards order.
bit offsets are specified with .b#, # being the bit offset
#.b#
byte offsets are specified with .#, # being the byte offset
#.#
mainly for registers / entries that support writing, such as the holding register for modbus
R = Read Only
RD = Read Disabled
W = Write