151 changes: 150 additions & 1 deletion src/devices/tuya.ts
Original file line number Diff line number Diff line change
Expand Up @@ -1214,7 +1214,7 @@
},
},
{
fingerprint: tuya.fingerprint("TS0601", ["_TZE284_vuwtqx0t", "_TZE200_vuwtqx0t"]),
fingerprint: tuya.fingerprint("TS0601", ["_TZE200_vuwtqx0t"]),
Copy link
Owner

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

To update this definition, revert this change and update the exposes and tuyaDatapoints like you did with the _TZE284_vuwtqx0t copy

model: "TS0601_water_valve",
vendor: "Tuya",
description: "Ultrasonic water meter valve",
Expand Down Expand Up @@ -1271,6 +1271,155 @@
exposes.options.calibration("temperature"),
],
},
{
fingerprint: [
{
modelID: "TS0601",
manufacturerName: "_TZE284_vuwtqx0t",
},
],
model: "TS0601_water_valve",
vendor: "Tuya",
description: "Ultrasonic water meter valve",
extend: [],
fromZigbee: [tuya.fz.datapoints],
// toZigbee: [tuya.tz.datapoints],
toZigbee: [tzdatapoints],

Check failure on line 1287 in src/devices/tuya.ts

View workflow job for this annotation

GitHub Actions / ci

Cannot find name 'tzdatapoints'.
onEvent: tuya.onEventSetTime,

Check failure on line 1288 in src/devices/tuya.ts

View workflow job for this annotation

GitHub Actions / ci

Property 'onEventSetTime' does not exist on type 'typeof import("/home/runner/work/zigbee-herdsman-converters/zigbee-herdsman-converters/src/lib/tuya")'.
configure: tuya.configureMagicPacket,
exposes: [
e.numeric("water_consumed", ea.STATE).withUnit("L").withDescription("Total water consumed").withValueMin(0).withValueStep(0.001),

// Need to fix this month and daily consumption - currently shows as JSON
e
.numeric("month_consumption", ea.STATE)
.withUnit("L")
.withDescription("month consumption")
.withValueMin(0)
.withValueStep(0.001),
e.numeric("daily_consumption", ea.STATE).withUnit("L").withDescription("daily consumption").withValueMin(0).withValueStep(0.001),

// Not sure what this does or how to change it
// e.numeric('month_and_daily_frozen_set', ea.STATE).withDescription('Month Daily Frozen Set'),

// I can't seem to get this to work - when i try to change the value i get an error in zigbee2mqtt, stuck on 1 Hour
e
.enum("report_period", ea.STATE_SET, ["1h", "2h", "3h", "4h", "6h", "8h", "12h", "24h"])
.withDescription("Report period"),
// e.text('warning', ea.STATE), // FIX THIS - BITMAP -> fault types

// These are attempts at getting the valve open/closed switch and the autoclean switch working together.
e
.binary("state", ea.STATE_SET, "ON", "OFF")
.withDescription("Valve position"),

// Autoclean switch - deactivated because I dont know how to get it working independently to the valve open/close switch
e
.binary("auto_clean", ea.STATE_SET, "ON", "OFF")
.withDescription("Auto Clean"),

// Note sure what this does - it wasnt in the tuya DP's extracted from the IOT portal?
// e.text('something', ea.STATE).withDescription('Something'),
// e.text('meter_id', ea.STATE).withDescription('Meter ID (ID of device)'),
// Reverse consumption and instantaneous flow are appearing as JSON, in tuya they are a Base 64 but I dont know how to get it to show correctly
// e.numeric('reverse_water_consumption', ea.STATE).withDescription('reverse water flow'),

e
.numeric("flow_rate", ea.STATE)
.withUnit("L/h")
.withDescription("Instantaneous water flow rate"),
//e.numeric('instantaneous_flow_rate', ea.STATE).withDescription('Inst flow rate'),

e
.temperature()
.withDescription("Water Temperature"),
e.numeric("battery_voltage", ea.STATE).withUnit("V").withDescription("Voltage Battery"),
],

meta: {
tuyaDatapoints: [
[1, "water_consumed", tuya.valueConverter.raw], // dtype number
// DP2 - month_consumption
[
2,
"month_consumption",
{
from: (v) => {
const buf = Buffer.isBuffer(v) ? v : Buffer.from(v || []);
if (buf.length >= 8) {
const value = (buf.readUInt8(4) << 24) + (buf.readUInt8(5) << 16) + (buf.readUInt8(6) << 8) + buf.readUInt8(7);
return value;
}
return 0;
},
},
],

// DP3 - daily_consumption
[
3,
"daily_consumption",
{
from: (v) => {
const buf = Buffer.isBuffer(v) ? v : Buffer.from(v || []);
if (buf.length >= 8) {
const value = (buf.readUInt8(4) << 24) + (buf.readUInt8(5) << 16) + (buf.readUInt8(6) << 8) + buf.readUInt8(7);
return value;
}
return 0;
},
},
],
[
4,
"report_period",
tuya.valueConverterBasic.lookup({
"1h": tuya.enum(0),
"2h": tuya.enum(1),
"3h": tuya.enum(2),
"4h": tuya.enum(3),
"6h": tuya.enum(4),
"8h": tuya.enum(5),
"12h": tuya.enum(6),
"24h": tuya.enum(7),
}),
], // dtype 4 - enum
//[5,'warning', tuya.dataTypes.enum], // bitmap,
//[6,'month_and_daily_frozen_set', tuya.valueConverter.raw], // dtype 0 - raw
//[13,'state', tuya.valueConverter.onOff], // Bool VALVE OPEN CLOSE
[13, "state", tuya.valueConverter.onOffNotStrict],
[14, "auto_clean", tuya.valueConverter.onOff], // Bool AUTOCLEAN SW - DISABLED UNTILL I CAN FIGURE IT OUT
//[15,'something', tuya.valueConverter.raw], // dtype 0 - raw - No idea what this does?
//[16,'meter_id', tuya.valueConverter.raw], //dtype 3 - raw METER ID
//[18,'reverse_water_consumption', tuya.valueConverter.raw], // dtype 0 - raw
[
21,
"flow_rate",
{
from: (v) => {
const buf = Buffer.isBuffer(v) ? v : Buffer.from(v || []);
if (buf.length >= 4) {
const value = buf.readUInt32BE(0);
return value;
}
return 0;
},
},
],
[22, "temperature", tuya.valueConverter.divideBy100],
[26, "battery_voltage", tuya.valueConverter.divideBy100],
],
},
// Optional: Add device-specific options
options: [
exposes.options.precision("water_consumed"),
exposes.options.calibration("water_consumed"),
exposes.options.precision("flow_rate"),
exposes.options.calibration("flow_rate"),
exposes.options.precision("temperature"),
exposes.options.calibration("temperature"),
],
},
{
fingerprint: tuya.fingerprint("TS0601", ["_TZE284_ajlu4cud"]),
model: "TS0601_water_meter",
Expand Down
Loading