Air Filter Upgrade

Upgraded control system for Axminster air filter units.

Usage

Button options (actions take effect when button is released):

  • quick (< 3 seconds) press start/demand button: start fan if stopped, or reset timer to 20 minutes if already running
  • long (>= 3 seconds) press start/demand button: stop fan
  • quick press speed button: cycle fan speed if running

Known issues

Sometimes the display can become unresponsive due to electrical noise from the contactors. A power cycle will fix this.

Wiring notes

From fan motor:

  • black = N
  • white = SL high speed
  • yellow = SL medium speed
  • blue = SL low speed