as I'm using in my installation. Please note, my setup is 3 solar fields connected to 2 inverters an each having a battery pack aside. Inverters are Goodwe ET6.5 and batteries are axitec 13.5kWh each.
axitec_hold.py links on
- allows to set an inverter to hold
- if set to hold the charging power is reduced to 100W
- it is set to hold if SoC is above 40%
- if hold is canceled, bms ist set to selfuse and 6000W
-
axitec_hold.py links off
charge_battery.py 75
- charges both inverters to target-SoC
- use this if dynamic prices are low in winter
- uses bms to charge battery from grid
- use this if i'm charging the car while dynamic price is low but don't want to drain the battery
-
charge_bms_on_off.py "on" 50
- keeps the battery in charging mode, discharging is not allowed
charge_bms_on_off.py "on" 6500
-
- charges battery with high priority from grid
- fetches all values from a goodwe inverter
- writes measurements in a influxdb
- works with dashboards delivered in json
GoodWe_Axited_xx
- some notes to registers used in my environment