Skip to content

Command sricpt to control the turning bench and the HB

Notifications You must be signed in to change notification settings

SwarmUS/TestBench-Python

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

74 Commits
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

TestBench-Python

This repo is the accumulation of many scripts needed in order to calibrate and validate a new set of Beeboard and Hiveboard. The python scripts are :

Installation

Prerequisites:

Each script has its own requirements.txt which permits the installation of the required packages

Normal order of operation

Follow this flow chart in order to find which script to run depending on your need:

ExtractRawData

This script enables the user to extract the raw DW1000 data from the HiveBoard/BeeBoards assembly. The test-bench will turn by a chosen stepping angle and acquire the desired amount of raw data per step.

Hardware setup

  • Place a BeeBoards assembly in the middle of the test-bench. The 0deg axis of the assembly needs to point in a parallel fashion to the mounted laser pointer.
    • The assembly is described as :
      • The BeeBoard mount
      • The 3 wings boards
      • The 3 USC-C cables
      • The HiveBoard
      • The channel used for each BeeBoard.
  • The BeeBoards have to be connected to a HiveBoard mounted to the test-bench using the same cable and ports as labeled on the assembly. If the cables and assembly are not indicated be sure to note which BeeBoards are used, plugged with which cables and in which channel on which HiveBoard. The calibration will only be valid for this configuration and has to be completly re-performed if any of this component is changed or plugged differently.
  • The BeeBoard assembly should be mounted as follow:
    If, for any reason, the antenna are not plugged in the same channel as asked per the hardware setup, absolutely refer to the angle documentation as everything is dependent on this.
  • Connect power and communication interface to the HiveBoard.
  • Ensure the HiveBoard has the latest version of the HiveMind
  • Connect a usb cable to the Arduino.
  • Connect power to the drive submodule (red = 12 V, white = ground)
  • To align the receiver with the emmiter, use the laser pointer. Each laser should point to the alignment target of the other laser assembly. This position ensures a 0 degree relative orientation between the two radio setup.
  • The laser mount should be calibrated periodicly to ensure its position and accuracy.
  • Press button 0 on the emmiter to enable the continuous sending mode.
  • Ensure that nothing is between the emmiter and the BeeBoard assembly (ensure line of sight).

Runnning the script

The script can be run from /src/extractRawData.
Requires the TestBench-Arduino code to be installed on the test-bench's Arduino in order to be interfaced.

Adjustable parameters

USE_ETHERNET : If True, the communication with the Hiveboard will be done from the Ethernet port. If False, the UART interface will be used, and the following line must be edited to match the port on which the Hiveboard is connected.

hb_stream = UsbStream('COM16')

The Arduino communicates through UART and the following line must be edited:

testbench = TurningStation('COM15', 115200)

name : suffix given to the produced CSV with the raw data.
stepSize : number of encoder ticks between each acquisition position.
num_frames : number of raw data frames to be acquisitioned at each position.
destination : ending position of the acquisition. The used encoder has 2048 tick per turn, 2050 should represent a single complete turn.
The data extracted will be saved upon completion of the acquisition once the destination has been reached. The saved data is found in the /src/data folder. Each CSV is timestamped and named using the name variable.

Once these parameters have been adjusted, the file can be run. The TurningStation should turn the amount entered in step and then stop for 3-5 seconds for the acquisition period before starting to turn again, repeting this cycle until destination has been reached. A complete turn takes usually around 15 minutes.

Note

Communication with the HiveBoard is done using the Pheromones submodule. If communication problems occur, ensure that the version used by the script is the same as on the HiveBoard.

Parser

Parses and presents the PDOA values from the previously acquired raw data (from ExtractRawData). The user will be prompted 2 clickable interfaces to firstly offset the data to a common reference and secondly to extract the slopes of each antenna pair.

Runnning the script

The script can be run from src/parser.

Adjustable parameters

dataFolderPath : folder path where the extracted raw data CSV produced by ExtractRawData has been saved.
dataName : name of the file to parse the data from, without the extension.
usedPairs : the antenna pairs to be used. Use 0,1 and 5 for default operation. Encoded as follow :

	pair 0 = antenna 0 - antenna 1
pair 1 = antenna 0 - antenna 2
pair 2 = antenna 1 - antenna 0
pair 3 = antenna 1 - antenna 2
pair 4 = antenna 2 - antenna 0
pair 5 = antenna 2 - antenna 1
Refer to the [angle documentation](https://swarmus.github.io/SwarmUS-doc/sections/reference/Interloc/how_it_works/angle/) for a better understanding of the antenna pairs and their selection. <br />

EXPORT_PDOA : True will prompt the second set of plots (slopes extraction) and save the calibration result in a pickle format.

Behavioral descriptionand user interaction

Upon runnning the script, the first plot to appear will ask the user to select points from which to offset the whole dataset. Theoretically, the plot should represent a sin wave. The goal is to offset the signal until it wraps minimally. If the sin is not wrapping, no points need to be selected, as no offset needs to be applied, simply close the plot. Otherwise, the points selected should then be the very bottom of a sin parabola section. Also, to obtain a better estimation of the offset needed, it is possible to select the very bottom of the parabola, and a top of this parabola that has wrapped over. Many points can be selected, the mean of the y axis will be used as the offset. This process has to be repeted for the number of usedPairs selected. Closing the plot will save the selection and present the following antenna pair plot. Here is an exemple of the process.

A plot of the result will then appear. If all curves are not wrapping, the first step is succesful. Otherwise, the script must be re-run and better points must be selected until all curves do not wrap.

The second set of plots is the extraction of the slopes caracteristics. This set will appear only if the EXPORT_PDOA has beed set to True. A minimum of two lines, and a maximum of three, must be drawn in order to represent the slopes of the data. To draw a line, clic on two points, preferably the farthest appart. Draw at least one line for the rising part and one line for the falling part. This process has to be repeted for the number of usedPairs selected. Here is an exemple of the process.

The saved data will appear in the dataFolderPath/angleParameters. Each antenna pair has its own pickle file. These files will also be refered as the calibration. A validation of these files can be done using the testRead function from the Exporter class.

Send_angle_params

Communicates to the Hiveboard the slope and caracteristics of the antenna pairs. Uses the pickle files created by Parser. These files need to be placed in the calibration folder using the hb_{HIVEBOARD_ID} notation.

Runnning the script

The script can be run from /src/send_angle_params.

Adjustable parameters

HIVEBOARD_ID : the identification number of the Hiveboard. Can be found either in the flash memory or written on the RJ45 connector.
MOUNT_ORIENTATION_OFFSET : the rotation offest, in degrees, applied to the Beeboard assembly between the Test-bench setup at which the calibration was made, and the orientation on the robot or final installation.
USE_ETHERNET : If true, the communication with the Hiveboard will be done from the Ethernet port. If false, the UART interface will be used, and the following line must be adjusted to match the port on which the Hiveboard is connected.

hb_stream = UsbStream('COM16')

Behavioral description

When the script is ran, the parameters in the calibration folder will be sent to the connected Hiveboard and saved in the flash memory. Thus, there is no need to re-send the parameters on every boot cycle. The calibration should be performed occasionally to ensure the system reliability.

Note

Communication with the HiveBoard is done using the Pheromones submodule. If communication problems occur, ensure that the version used by the script is the same as on the HiveBoard.

Visualization

When a calibration has been completly transfered to the correspondant Hiveboard, this tool can be used to manually and visually confirm the effectiveness of the calibration. Using a emmiter, the user can move around the calibrated Hiveboard/BeeBoards assembly and see a marker representing the emmiter move around.

To use the tool, you will need one stationary HiveBoard with its BeeBoards and at least one mobile HiveBoard/BeeBoard assembly.

The stationary HiveBoard must be powered by the barrel connector (not by USB). Plug the Micro-USB cable to your computer for the serial connection.

Next, start the mobile HiveBoard/BeeBoards assembly.

To start the tool, start src/visualisation_tool. By default, the visualization tool will use the com port /dev/ttyACM0. To edit this value, edit the COM_PORT variable in DataUpdater.py.

The visualization tool will open a window with an orange dot at the center, representing the stationary HiveBoard. The mobile HiveBoard assemblies will show as coloured circles and their position will be updated at regular intervals. Specific neighbors can be hidden by unchecking the 'visible' check box in the table underneath the graph.

Note

Communication with the HiveBoard is done using the Pheromones submodule. If communication problems occur, ensure that the version used by the script is the same as on the HiveBoard.

Validate

This is a method to test the whole angles system of the interlocalisation. Using the exact same hardware setup as the calibration it is possible to extract the angle value result from the whole acquisition, linearisation and certitude algorithm. Using the test-bench assembly will automate this procedure.

Runnning the script

The script can be run from src/validate_interloc.
Requires the TestBench-Arduino code to be installed on the test-bench's Arduino in order to be interfaced.

Hardware setup

Refer to the ExtractRawData hardware setup section for the protocol to ensure precise data acquisition.

Adjustable parameters

REMOTE_HB_ID: ID of the emmiter used for the validation. As many HiveBoard can be detected, the scripts filters only the one needed by the user.
NUM_DATA_POINTS_PER_ANGLE:number of cycles to do at each angle position. Each cycles output a single angle value.
USE_ETHERNET : If True, the communication with the Hiveboard will be done from the Ethernet port. If False, the UART interface will be used, and the following line must be edited to match the port on which the Hiveboard is connected.

hb_stream = UsbStream('/dev/ttyACM0')

The Arduino communicates through UART and the following line must be edited:

testbench = TurningStation('/dev/ttyACM1', 115200)

stepSize : number of encoder ticks between each acquisition position.
destination : ending position of the acquisition. The used encoder has 2048 tick per turn, 2050 should represent a single complete turn.
The data extracted will be saved upon completion of the acquisition once the destination has been reached.

Behavioral description

Similarly to ExtractRawData, the TurningStation will turn by the stepSize incrementation until it reaches the destination encoder tick. At each increment, the interlocalisation is enabled and produces NUM_DATA_POINTS_PER_ANGLE angles. These values are the one that would be propagated in the system in a typical use case. For a complete description of the process behind these values, please refer to Swarmus official interlocalisation documentation.

Results

The saved data is found in the /src/data folder. Each CSV is timestamped and named using the "validation_" prefix. For a visual analysis of the data, 3 plots have already been created. Running src/analysis/analyze_interloc_validation will produce:

  • A representation of the acquired angles for each position.
  • The error between the calculated angle and the actual orientation of the emmiter.
  • The standard deviation of the angles calculated at each position.
    To select which file to analyze, edit :
analyze_validation("../data/validation_hb6.csv")

Note

Communication with the HiveBoard is done using the Pheromones submodule. If communication problems occur, ensure that the version used by the script is the same as on the HiveBoard.