Documentation for new OpenTherm component #3800

Merged
merged 39 commits into from
Nov 12, 2024
Merged
Show file tree
Hide file tree
Changes from 19 commits
Commits
Show all changes
39 commits
Select commit Hold shift + click to select a range
e0ff0c2
Added documentation for new OpenTherm component
olegtarasov Apr 26, 2024
b813b36
Removed external component reference
olegtarasov Apr 26, 2024
736ea41
Fixed linter errors
olegtarasov Apr 26, 2024
c060d33
Edited sensor name
olegtarasov May 16, 2024
a60aea5
Merge branch 'next' into opentherm-next-docs
olegtarasov May 16, 2024
2488c4b
Merge branch 'next' into opentherm-next-docs
olegtarasov May 20, 2024
b54d6f5
Merge branch 'next' into opentherm-next-docs
olegtarasov Jun 9, 2024
407ab79
Merge branch 'next' into opentherm-next-docs
olegtarasov Jun 16, 2024
724c13c
Merge branch 'opentherm-next-docs' of github.com:olegtarasov/esphome-…
olegtarasov Jun 16, 2024
17a1f22
Merge branch 'next' into opentherm-next-docs
olegtarasov Jun 23, 2024
bc48ed6
Merge branch 'next' into opentherm-next-docs
olegtarasov Jun 29, 2024
4152085
Merge branch 'next' into opentherm-next-docs
olegtarasov Jul 7, 2024
c01c6ae
Added info on sync mode
olegtarasov Jul 7, 2024
cb990f5
Merge branch 'next' into opentherm-next-docs
olegtarasov Jul 23, 2024
dddaea8
Merge branch 'next' into opentherm-next-docs
olegtarasov Aug 3, 2024
e193c99
Added new sensors to docs
olegtarasov Aug 4, 2024
9c4084d
Merge branch 'opentherm-next-docs' of github.com:olegtarasov/esphome-…
olegtarasov Aug 4, 2024
5cedc13
Merge branch 'next' into opentherm-next-docs
olegtarasov Aug 23, 2024
cc58537
Merge branch 'next' into opentherm-next-docs
olegtarasov Aug 29, 2024
10058d2
Apply suggestions from code review
olegtarasov Sep 11, 2024
b5a1dfd
Merge branch 'next' into opentherm-next-docs
olegtarasov Sep 11, 2024
d8c344f
Merge branch 'next' into opentherm-next-docs
olegtarasov Sep 14, 2024
9a9815c
Wrapped the lines at 120 chars
olegtarasov Sep 14, 2024
9b7f520
Merge branch 'opentherm-next-docs' of github.com:olegtarasov/esphome-…
olegtarasov Sep 14, 2024
09ce10d
Formatting fixes
kbx81 Sep 14, 2024
5aa8f61
Remove extra whitespace
kbx81 Sep 14, 2024
0fdf5c9
Clarified the example
olegtarasov Sep 14, 2024
ba19922
Added more details to describe existing inputs. Also added new sensor…
olegtarasov Oct 1, 2024
5f502b4
Merge branch 'next' into opentherm-next-docs
olegtarasov Oct 1, 2024
45fb00f
Fixed an error in the example
olegtarasov Oct 9, 2024
1e7391d
Merge branch 'opentherm-next-docs' of github.com:olegtarasov/esphome-…
olegtarasov Oct 9, 2024
5db082d
Clarified numerical values terminology, added new sensors
olegtarasov Oct 31, 2024
bc5af84
Merge branch 'next' into opentherm-next-docs
olegtarasov Oct 31, 2024
6b137ae
Added `opentherm_version` to OpenTherm documentation
olegtarasov Nov 5, 2024
cf15a64
Merge branch 'opentherm-next-docs' of github.com:olegtarasov/esphome-…
olegtarasov Nov 5, 2024
5081fc2
Replaced References section with standard See Also
olegtarasov Nov 11, 2024
6d92766
Edited apiref links
olegtarasov Nov 11, 2024
061d918
Further edits
olegtarasov Nov 11, 2024
5e7af2b
Merge branch 'next' into opentherm-next-docs
olegtarasov Nov 11, 2024
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
Binary file added components/images/opentherm-shield.png
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
363 changes: 363 additions & 0 deletions components/opentherm.rst
Original file line number Diff line number Diff line change
@@ -0,0 +1,363 @@
OpenTherm
=========

.. seo::
:description: Instructions for setting up OpenTherm bridge in ESPHome.
:image: ../components/images/opentherm-shield.png
:keywords: OpenTherm

OpenTherm (OT) is a standard communications protocol used in central heating systems for the communication between a central heating appliances and a thermostatic controller.
As a standard, OpenTherm is independent of any single manufacturer. A controller from manufacturer A can in principle be used to control a boiler from manufacturer B.

Since OpenTherm doesn't operate in a standard voltage range, special hardware is required. You can choose from several ready-made adapters or roll your own:

- `DIYLESS Master OpenTherm Shield <https://diyless.com/product/master-opentherm-shield>`__
- `Ihor Melnyk's OpenTherm Adapter <http://ihormelnyk.com/opentherm_adapter>`__
- `Jiří Praus' OpenTherm Gateway Arduino Shield <https://www.tindie.com/products/jiripraus/opentherm-gateway-arduino-shield/>`__ .

.. figure:: images/opentherm-shield.png
:align: center
:width: 50.0%

DIYLESS Master OpenTherm Shield.

.. note::

This component acts only as an OpenTherm master (i.e. a thermostat or controller) and not as a slave or gateway. You can no longer use your existing thermostat if you control your boiler through ESPHome with this component.

Quick glossary
--------------

- CH: Central Heating
- DHW: Domestic Hot Water

Hub
---

First of all you need to define the OpenTherm hub in your configuration. Note that most OpenTherm adapters label ``in`` and ``out`` pins relative to themselves, and this component labels its ``in`` and ``out`` pins relative to ESP board. So usually your bridge's ``in`` pin becomes hub's ``out`` pin and vice versa.

.. code-block:: yaml

opentherm:
in_pin: 4
out_pin: 5

Configuration variables:
************************

- **in_pin** (**Required**, number): The pin of the OpenTherm hardware bridge which is usually labeled ``out`` on the board.
- **out_pin** (**Required**, number): The pin of the OpenTherm hardware bridge which is usually labeled ``in`` on the board.
- **sync_mode** (**Optional**, boolean, default **false**): Synchronous communication mode prevents other components from disabling interrupts while we are talking to the boiler. Enable if you experience a lot of random intermittent invalid response errors (very likely to happen while using Dallas temperature sensors).
- **id** (*Optional*, :ref:`config-id`): Manually specify the ID used for code generation. Required if you have multiple busses.

Note abut sync mode
*******************

By default this component adheres to ESPHome recommendations and doesn't block the loop while communicating with the boiler. Unfortunately, some other components (like Dallas temperature sensors) don't play well with this behaviour, and may cause a lot of lost frames and protocol warnings from OpenTherm. Since OpenTherm is resilient by design and transmits its messages in a constant loop, these dropped frames don't really matter. But if you want to decrease the number of protocol warnings in your logs, you can enable ``sync_mode``, which blocks ESPHome loop until a single conversation with the boiler is complete. This can greatly reduce the number of dropped frames, but usually doesn't eliminate them entirely. You also need to add a logging directive to your config, so that ESPHome doesn't complain about a single component hogging the loop for too long:

.. code-block:: yaml

logger:
logs:
component: ERROR

Usage as a thermostat
---------------------

The most important function for a thermostat is to set the boiler temperature setpoint. This component has three ways to provide this input: using a Home Assistant sensor from which the setpoint can be read, using a :doc:`/components/number/index`, or defining an output to which other components can write. For most users, the last option is the most useful one, as it can be combined with the :doc:`/components/climate/pid` component to create a thermostat that works as you would expect a thermostat to work. See :ref:`thermostat-pid-basic` for an example.

Numerical input
***************

There are three ways to set an input value:

- As an input sensor, defined in the hub configuration:

.. code-block:: yaml

opentherm:
t_set: setpoint_sensor

sensor:
- platform: homeassistant
id: setpoint_sensor
entity_id: sensor.boiler_setpoint

This can be useful if you have an external thermostat-like device that provides the setpoint as a sensor.

- As a number:

.. code-block:: yaml

number:
- platform: opentherm
t_set:
name: Boiler Setpoint

This is useful if you want full control over your boiler and want to manually set all values.

- As an output:

.. code-block:: yaml

output:
- platform: opentherm
t_set:
id: setpoint

This is especially useful in combination with the PID Climate component:

.. code-block:: yaml

climate:
- platform: pid
heat_output: setpoint
# ...

For the output and number variants, there are four more properties you can configure beyond those included in the output and number components by default:

- ``min_value`` (float): The minimum value. For a number this is the minimum value you are allowed to input. For an output this is the number that will be sent to the boiler when the output is at 0%.
- ``max_value`` (float): The maximum value. For a number this is the maximum value you are allowed to input. For an output this is the number that will be sent to the boiler when the output is at 100%.
- ``auto_max_value`` (boolean): Automatically configure the maximum value to a value reported by the boiler. Not available for all inputs.
- ``auto_min_value`` (boolean): Automatically configure the minimum value to a value reported by the boiler. Not available for all inputs.

The following inputs are available:

- ``t_set``: Control setpoint: temperature setpoint for the boiler's supply water (°C)
- ``t_set_ch2``: Control setpoint 2: temperature setpoint for the boiler's supply water on the second heating circuit (°C)
- ``cooling_control``: Cooling control signal (%)
- ``t_dhw_set``: Domestic hot water temperature setpoint (°C)
- ``max_t_set``: Maximum allowable CH water setpoint (°C)
- ``t_room_set``: Current room temperature setpoint (informational) (°C)
- ``t_room_set_ch2``: Current room temperature setpoint on CH2 (informational) (°C)
- ``t_room``: Current sensed room temperature (informational) (°C)

Switch
******

For five status codes, switches are available to toggle them manually. The same values can be set in the hub configuration, like so:

.. code-block:: yaml

opentherm:
ch_enable: true
dhw_enable: true

This can be used to set the value without the need for a switch if you'd never want to toggle it after the initial configuration.
The default values for these configuration options are listed below.

For enabling of central heating and cooling, the enable-flag is only sent to the boiler if the following conditions are met:
- the flag is set to true in the hub configuration,
- the switch is on, if it is configured,
- the setpoint or cooling control value is not 0, if it is configured.

For domestic hot water and outside temperature compensation, only the first two conditions are necessary.

The last point ensures that central heating is not enabled if no heating is requested as indicated by a setpoint of 0. If you use a number as the setpoint input and use a minimum value higher than 0, you NEED to use the ch_enable switch to turn off your central heating. In that case the flag will be set to true in the hub configuration, and setpoint is always larger than 0, so including a switch is the only way you can turn off central heating. (This also holds for cooling and CH2.)

The following switches are available:

- ``ch_enable``: Central Heating enabled
- ``dhw_enable``: Domestic Hot Water enabled
- ``cooling_enable``: Cooling enabled
- ``otc_active``: Outside temperature compensation active
- ``ch2_active``: Central Heating 2 active

Binary sensor
*************

The component can report boiler status on several binary sensors. The *Status* sensors are updated in each message cycle, while the others are only set during initialization, as they are unlikely to change without restarting the boiler.

- ``fault_indication``: Status: Fault indication
- ``ch_active``: Status: Central Heating active
- ``dhw_active``: Status: Domestic Hot Water active
- ``flame_on``: Status: Flame on
- ``cooling_active``: Status: Cooling active
- ``ch2_active``: Status: Central Heating 2 active
- ``diagnostic_indication``: Status: Diagnostic event
- ``dhw_present``: Configuration: DHW present
- ``control_type_on_off``: Configuration: Control type is on/off
- ``cooling_supported``: Configuration: Cooling supported
- ``dhw_storage_tank``: Configuration: DHW storage tank
- ``controller_pump_control_allowed``: Configuration: Controller pump control allowed
- ``ch2_present``: Configuration: CH2 present
- ``dhw_setpoint_transfer_enabled``: Remote boiler parameters: DHW setpoint transfer enabled
- ``max_ch_setpoint_transfer_enabled``: Remote boiler parameters: CH maximum setpoint transfer enabled
- ``dhw_setpoint_rw``: Remote boiler parameters: DHW setpoint read/write
- ``max_ch_setpoint_rw``: Remote boiler parameters: CH maximum setpoint read/write

Sensor
******

The boiler can also report several numerical values, which are available through sensors. Your boiler may not support all of these values, in which case there won't be any value published to that sensor. The following sensors are available:

- ``rel_mod_level``: Relative modulation level (%)
- ``ch_pressure``: Water pressure in CH circuit (bar)
- ``dhw_flow_rate``: Water flow rate in DHW circuit (l/min)
- ``t_boiler``: Boiler water temperature (°C)
- ``t_dhw``: DHW temperature (°C)
- ``t_outside``: Outside temperature (°C)
- ``t_ret``: Return water temperature (°C)
- ``t_storage``: Solar storage temperature (°C)
- ``t_collector``: Solar collector temperature (°C)
- ``t_flow_ch2``: Flow water temperature CH2 circuit (°C)
- ``t_dhw2``: Domestic hot water temperature 2 (°C)
- ``t_exhaust``: Boiler exhaust temperature (°C)
- ``fan_speed``: Boiler fan speed (RPM)
- ``flame_current``: Boiler flame current (µA)
- ``burner_starts``: Number of starts burner
- ``ch_pump_starts``: Number of starts CH pump
- ``dhw_pump_valve_starts``: Number of starts DHW pump/valve
- ``dhw_burner_starts``: Number of starts burner during DHW mode
- ``burner_operation_hours``: Number of hours that burner is in operation
- ``ch_pump_operation_hours``: Number of hours that CH pump has been running
- ``dhw_pump_valve_operation_hours``: Number of hours that DHW pump has been running or DHW valve has been opened
- ``dhw_burner_operation_hours``: Number of hours that burner is in operation during DHW mode
- ``t_dhw_set_ub``: Upper bound for adjustment of DHW setpoint (°C)
- ``t_dhw_set_lb``: Lower bound for adjustment of DHW setpoint (°C)
- ``max_t_set_ub``: Upper bound for adjustment of max CH setpoint (°C)
- ``max_t_set_lb``: Lower bound for adjustment of max CH setpoint (°C)
- ``t_dhw_set``: Domestic hot water temperature setpoint (°C)
- ``max_t_set``: Maximum allowable CH water setpoint (°C)


Examples
--------

Minimal example with numeric input
**********************************

.. code-block:: yaml

# An extremely minimal configuration which only enables you to set the boiler's
# water temperature setpoint as a number.

esphome:
name: thermostat-number-minimal

esp8266:
board: d1_mini

logger:

api:
ota:
wifi:
ap:
ssid: "Thermostat"
password: "MySecretThemostat"

opentherm:
in_pin: 21
out_pin: 26

number:
- platform: opentherm
t_set:
name: "Boiler Control setpoint"

.. _thermostat-pid-basic:

Basic PID thermostat
********************

.. code-block:: yaml

# A basic thremostat for a boiler with a single central heating circuit and
# domestic hot water. It reports the flame, CH and DHW status, similar to what
# you would expect to see on a thermostat and also reports the internal boiler
# temperatures and the current modulation level. The temperature is regulated
# through a PID Climate controller and the current room temperature is retrieved
# from a sensor in Home Asisstant.

# This configuration should meet most needs and is the recommended starting
# point if you just want a thermostat with an external temperature sensor.

esphome:
name: thermostat-pid-basic

esp8266:
board: d1_mini

logger:

api:
ota:
wifi:
ap:
ssid: "Thermostat"
password: "MySecretThemostat"

opentherm:
in_pin: 21
out_pin: 26
ch_enable: true
dhw_enable: true

output:
- platform: opentherm
t_set:
id: t_set
min_value: 20
max_value: 65
zero_means_zero: true

sensor:
- platform: opentherm
rel_mod_level:
name: "Boiler Relative modulation level"
t_boiler:
name: "Boiler water temperature"
t_ret:
name: "Boiler Return water temperature"

- platform: homeassistant
id: ch_room_temperature
entity_id: sensor.temperature
filters:
# Push room temperature every second to update PID parameters
- heartbeat: 1s

binary_sensor:
- platform: opentherm
ch_active:
name: "Boiler Central Heating active"
dhw_active:
name: "Boiler Domestic Hot Water active"
flame_on:
name: "Boiler Flame on"
fault_indication:
name: "Boiler Fault indication"
entity_category: diagnostic
diagnostic_indication:
name: "Boiler Diagnostic event"
entity_category: diagnostic

switch:
- platform: opentherm
ch_enable:
name: "Boiler Central Heating enabled"
mode: restore_default_on

climate:
- platform: pid
name: "Central heating"
heat_output: t_set
default_target_temperature: 20
sensor: ch_room_temperature
control_parameters:
kp: 0.4
ki: 0.004

References
----------

This component was forked from Arthur Rump's ``esphome-opentherm`` component, which now seems to be abandoned. I replaced the underlying OpenTherm library with
code form Jiří Praus. I also did a lot of refactoring to bring the code closer to ESPHome coding standard.

- `Original Arthur Rump's repository <https://github.com/arthurrump/esphome-opentherm>`__
- `arduino-opentherm project by Jiří Praus <https://github.com/jpraus/arduino-opentherm>`__

There is also my blog post with more background details and reasoning for automating an OpenTherm boiler with ESPHome:

- `OpenTherm thermostat with ESPHome and Home Assistant <https://olegtarasov.me/opentherm-thermostat-esphome/>`__
Binary file added images/opentherm.png
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
1 change: 1 addition & 0 deletions index.rst
Original file line number Diff line number Diff line change
Expand Up @@ -260,6 +260,7 @@ Hardware Peripheral Interfaces/Busses
SPI Bus, components/spi, spi.svg
UART, components/uart, uart.svg
1-Wire, components/one_wire, one-wire.svg
OpenTherm, components/opentherm, opentherm.png

I/O Expanders/Multiplexers
--------------------------
Expand Down